摘要
AIM:To compare the visual performance of pseudophakic eyes implanted with Al-UV and SN60WF aspheric intraocular lens(IOL),and to investigate the correlations between visual quality parameters and pupil size.METHODS:This prospective comparative study included 105 eyes of 90 patients with age-related cataract who underwent uneventful phacoemulsification.The subjects were divided into two groups according to the implanted IOL type.Three months postoperatively,visual acuity and contrast sensitivity were measured,wave-front aberrations were assessed using a KR-IW aberrometer(Topcon),and objective optical quality parameters were performed using an optical quality analysis system-OQAS Il(Visiometrics).Independent sample Mest and Spearman correlation analysis were used for data analysis.RESULTS:There were no significant differences found in visual acuity,contrast sensitivity and visual quality parameters between the two groups(P>0.05).The measured intraocular spherical aberration(SA)in Al-UV IOL eyes of-0.19±0.05 pm was close to the designed SA value of-0.20 pm.The modulation transfer function cutoff,Strehl ratio and OQAS values were negatively correlated with pupil size in both groups(P<0.01).CONCLUSION:The subjective and objective visual quality in pseudophakic eyes with A1-UV and SN60WF IOLs are comparable.For aspheric IOL eyes,visual quality decreases with increasing pupil size.
基金
Supported by Project of Science&Technology Department of Sichuan Province(No.2019YJ0381)
Key Project of Sichuan Health and Family Planning Commission(No.18ZD022).