摘要
我国西北地区以750 kV电压等级构建骨干网架,尤其是新疆750 kV电网的建设,使得变电站之间的供电距离接近供电极限,高压侧/中压侧(750 kV/220 kV)级差较大,短路电流控制困难,因此,站址选择需要考虑的因素较其它电压等级更多、更复杂。文章结合新疆实际情况,分析影响750 kV变电站规划选址的六个关键因素,运用层次分析法建立评价体系模型,构建判断矩阵,对站址选择问题进行量化分析,从而获得更符合客观因素的最佳方案。
In Northwest China,the backbone grid is constructed with 750 kV voltage grade,especially the construction of Xinjiang 750kV power grid,which makes the power supply distance between substations close to the power supply limit,the high/medium(750 kV/220 kV)voltage level difference is large,and the short-circuit current control is difficult.Therefore,the factors that need to be considered in location selection are more and more complicated than other voltage grades.Combined with the actual situation of Xinjiang,this paper analyzes the six key factors affecting the planning location selection of 750 kV substation,establishes the evaluation system model with the analytic hierarchy process,constructs the judgment matrix,and carries on the quantitative analysis of the location selection problem,so as to obtain the best plan which is better in line with the objective factors.
作者
罗勋
刘新刚
郭文斌
LUO Xun;LIU Xin-gang;GUO Wen-bin(Xinjiang University,Urumqi 830047,China;Xinjiang Electric Power Design Institute Co.,Ltd.of CEEC,Urumqi 830001,China;State Grid Xinjiang Electric Power Co.,Ltd.,Urumqi 830063,China)
出处
《电力勘测设计》
2021年第3期38-44,共7页
Electric Power Survey & Design
关键词
变电站站址
层次分析法
判断矩阵
短路电流
substation location
analytic hierarchy process
judgment matrix