某超高层综合体工程由两栋超高层办公楼及多层裙房组成,裙房主要功能为商务配套和会议室。对该工程消防给水系统设计内容进行了分析,并对消防给水系统设计中的几个关键性设计要点进行了探讨,提出了一些提高系统安全可靠性的技术措施,对于提高超高层建筑消防给水系统的安全可靠性有重要作用。
A super high rise complex engineering consists of two super high-rise office buildings and multi-storey podium,whose main functions were business supporting and conference room.This paper analyzed the design content of fire water supply system of the engineering,discussed several key design points in fire water supply system design,put forward some technical measures to improve the system safety and reliability,played important role in improving the safety and reliability of fire water supply system of super high-rise buildings.