期刊文献+

高磁场磁共振超导磁体电源的拓扑设计与分析 被引量:2

Topology design and analysis of high field magnetic resonance superconducting magnet power supply
下载PDF
导出
摘要 针对高磁场磁共振大孔径人体成像系统中超导磁体电源在励磁时向磁体充能、退磁时把能量"逆变"回电网的设计要求,比较了两种能量回馈型的拓扑结构。通过Matlab仿真分析,验证了拟采用的拓扑结构的合理性。 The power supply of high field magnetic resonance superconducting magnet in a large aperture human body imaging system works in two aspects,i.e.normal excitation and demagnetization.The demagnetization energy is returned to the power grid through the"inversion"of the power supply.According to the design requirements,two kinds of energy feedback topologies are analyzed and compared.The proposed topology is analyzed and simulated with the Matlab/Simulink analysis.
作者 代天立 周超 秦经刚 李建刚 高格 DAI Tian-li;ZHOU Chao;QIN Jing-gang;LI Jian-gang;GAO Ge(Institute of Plasma Physics,ChineseAcademy of Sciences,Hefei 230031;University of Science and Technology of China,Hefei 230036)
出处 《核聚变与等离子体物理》 CAS CSCD 北大核心 2021年第1期72-77,共6页 Nuclear Fusion and Plasma Physics
基金 中国科学院“未来高场磁体技术发展研究”战略先导专项B类专项(Y15YZ53291)。
关键词 高磁场磁共振 超导磁体 脉冲宽度调制整流 H桥电路 LCR滤波器 High field magnetic resonance Superconducting magnet PWM rectifier H-bridge circuit LCR filter
  • 相关文献

参考文献3

二级参考文献17

共引文献60

同被引文献19

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部