摘要
目的分析和评价≥75岁患者心血管植入型电子器械(CIED)感染后经静脉起搏系统移除术的有效性及安全性。方法回顾性分析南京鼓楼医院2013年1月至2019年10月行经静脉起搏系统移除术的患者资料,根据年龄分为≥75岁组和<75岁组。对比两组患者的性别、伴随疾病、植入设备类型、导线根数及种类、麻醉方法、移除方式、并发症发生率及完全移除率等特征。结果研究入选316例患者,其中≥75岁组115例(男79例),<75岁组201例(男151例);<75岁组移除的除颤装置更多(10.9%对4.3%,P=0.044)。①两组患者在麻醉方式、手术时间、多根导线患者的比例、导线植入时间及拔除方式均差异无统计学意义。②安全性评估:两组患者均无住院期间死亡事件发生,≥75岁组有7例(6.1%,7/115)出现轻度并发症,无严重并发症发生;<75岁组有10例(5.0%,10/201)出现轻度并发症,1例(0.5%,1/201)出现严重并发症。③有效性评估:≥75岁组中111例(96.5%,111/115)患者起搏系统经静脉完全移除,4例(3.5%,4/115)取得临床成功,无移除失败事件;<75岁组中191例(95.0%,191/201)患者起搏系统完全移除,9例(4.5%,9/201)取得临床成功,1例(0.5%,1/201)经静脉移除失败。安全性及有效性评估差异无统计学意义。结论对于CIED感染的≥75岁患者,行经静脉起搏系统移除术是可行的,安全性和有效性并不亚于<75岁人群。
Objective To explore the safety and efficiency of transvenous lead extraction of cardiovascular implantable electronic devices(CIED)related infection in elderly patients.Methods A retrospective review was conducted on the patients with CIED related infection who underwent transvenous lead extraction from January 2013 to October 2019 in Nanjing Drum Tower Hospital.These patients compromised≥75 years old group and<75 years old group.The differences in gender,comorbidities,type of implanted devices,number and type of leads,anesthesia method,extraction methods,incidence of complications and complete removal rate between the two groups were analyzed and compared.Results A total of 316 patients were enrolled.Amond them,115 patients were in≥75 years old group,79 cases male.And 201 patients were under 75 years old,151 cases male.There were more defibrillation device in the<75 years old group(10.9%vs.4.3%,P=0.044).Safety evaluation:there were no death events during hospitalization in both groups.Seven cases(6.1%,7/115)of≥75 years old group had mild complications,no serious complications.Ten cases(5.0%,10/201)of<75 years old group had mild complications,and 1 case had serious complications.Effectiveness evaluation:111 patients(96.5%,111/115)in≥75 years old group had complete removal of pacing system.Four patients(3.5%,4/115)achieved clinical success without removal failure.And 191 patients(95.0%,191/201)in<75 years old group had complete removal of pacing system,9 patients(4.5%,9/201)had clinical success,and 1 cases(0.5%,1/201)failed to remove pacing system.There was no significant difference in the evaluation of safety and effectiveness.Conclusion For the patients≥75 years old with CIED infection,transvenous lead extraction is an effective and safe way.
作者
郑甲
蓝荣芳
徐伟
Zheng Jia;Lan Rongfang;Xu Wei(Department of Cardiology,Nanjing Drum Tower Hospital,The Affiliated Hospital of Nanjing University Medical School,Nanjing 210008,China)
出处
《中华心律失常学杂志》
2021年第1期77-81,共5页
Chinese Journal of Cardiac Arrhythmias
关键词
感染
心血管植入型电子器械
导线
移除
高龄患者
Infect
Cardiovascular implantable electronic devices
Lead
Extraction
Elderly patients