摘要
Cone-beam computerized tomography(CBCT)is an effective technique for assessment of changes to the alveolar ridge(AR).However,its accuracy and reliability could be improved by standardization of imaging positions to remain unchanged during measurements.In this study,an alveolar ridge preservation procedure was performed on a left third molar(38)socket by filling it with a radiotransparent synthetic bone graft,mineralized collagen(MC).Photographic,X-ray and CBCT images were captured before and 3,6 and 12 months after surgery.A new method was developed to standardize CBCT for quantitative evaluation.Obtained CBCT images showed good comparability.The post-extraction alveolar width and height were both over 95%of the original values,but some resorption of the lingual bone wall(>50%)and inter-crestal bone(>30%).It is concluded that an effective positional standardization method was developed for CBCT assessment of AR dimensional changes in the posterior mandible.The use of MC in combination with a collagen membrane improved dimensional preservation of the AR.
基金
This work was supported by grants from the Outstanding Medical Academic Leader Program and Creative Team of Jiangsu Province,the Project Funded by the Priority Academic Program Development of Jiangsu Higher Education Institutions(PAPD,2014-37)
the National Natural Science Foundation of China(No.81400486)
the Natural Science Foundation of Jiangsu Province(No.BK20140911)
the Postdoctoral Science Foundation of Jiangsu Province(No.1402044B)
the China Postdoctoral Science Foundation(No.2015M571647).