期刊文献+

核电站应急柴油发电机组调速系统对电气指标的影响 被引量:2

The Influence of the Speed Control System of Emergency Diesel Gensets in a Nuclear Power Station on Electric Indexes
下载PDF
导出
摘要 针对某核电站应急柴油发电机组在进行BASS55试验时机组频率恢复时间超差的问题开展相关试验研究。试验表明:发电机组在应急启动时突加较大感性负载,容易造成低频及稳态恢复时间超差等问题;通过优化匹配电子调速器的PID控制参数,可使机组的电气指标满足技术要求;柴油机以及调试系统、发电机以及励磁系统等是影响应急柴油发电机组电气指标随机组突加负载变化的主要因素。 During the BASS55 test of the emergency diesel gensets in a nuclear power station,the frequency recovery time of the gensets was beyond the tolerance.Research was carried out to deal with this problem.The test results show that in emergency start,there was sudden big inductive load on the gensets,which may lead to the problems such as low frequency and over recovery time of steady state.Through optimization of the PID control parameters of electronic speed controller,the electric indexes of the gensets could meet with the technical requirements.Diesel engines and debug systems,gensets and excitation systems are the main factors to influence the electric indexes of emergency diesel gensets.
作者 李建武 姜烨 Li Jianwu;Jiang Ye(Xi'an Nuclear Emergency Equipment Co.,Ltd.,Shaanxi Xi'an 710075)
出处 《柴油机》 2021年第2期38-41,共4页 Diesel Engine
关键词 应急柴油发电机组 调速器 PID控制 电气指标 emergency diesel genset speed controller PID control electric index
  • 相关文献

参考文献2

二级参考文献6

  • 1宋恩哲,姚崇,孙军.智能增益修正改进电控柴油机调速性能的研究[J].船舶工程,2006,28(3):82-84. 被引量:8
  • 2张国德.PLC原理及应用[M].机械工业出版社.
  • 3熊信银.发电厂电气部分(第三版)[M].中国电力出版社.
  • 4[苏]塔岗诺夫,著.船舶电站暂态过程的工程计算[M]. 国防工业出版社, 1976
  • 5J.J.Dai,Di Xiao,etc.Emergency generator start-up studyfor a nuclear generation facility[].Industrial and CommercialPower Systems Technical Conference Annual Meeting.2002
  • 6.RCC_E Design and Conception Rules for Electrical Equip-ments of Nuclear Islands[]..2002