期刊文献+

焦化废水中水回用工艺中反渗透膜污染清洗应用 被引量:6

Reverse Osmosis Membrane Fouling Cleaning in Recycling Technology of Coking Wastewater
下载PDF
导出
摘要 采用双膜法工艺处理焦化废水,实现中水回用。项目选用型号DOWTM BW30XFR-400/34i卷式反渗透膜,初始运行通量16 LMH,经过6月运行后,通量下降>95%。膜元件采用浸泡方式能极大程度地提高清洗效果,采用LC-07强酸型清洗剂对膜通量恢复和截留率的提升效果显著,膜元件截留率可以由清洗前的57.23%稳定恢复至>90%。SEM结果显示,清洗后膜表面仍然残留有少量的污染物,ATR-FTIR谱图显示经化学清洗后,聚砜支撑层的O=S=O对称伸缩振动峰发生明显红移,酰胺I和酰胺II特征峰整体发生蓝移,可能是膜面污染物的存在导致特征基团的电子跃迁。 Double-membrane process was used for coking wastewater reuse,the DOWTM BW30XFR-400/34i series reverse osmosis membrane was selected in the project.In comparison with new BW30XFR membrane module,the flux decreased more than 95%for the fouled membrane module.It was found that the recovery of membrane capability required repeated and long-term chemical cleaning.The soaking method could improve the cleaning effect greatly.LC-07 could remarkable effect on membrane characteristics with more than 95%flux recovery.The rejection of membrane increases to more than 90%after chemical cleaning,contrast with 57.23%of fouled membrane.As shown in SEM results,there were still membrane foulants on the membrane surface.ATR-FTIR spectra showed that after chemical cleaning,the O=S=O symmetrical stretching vibration peak of the support layer of polysulfone had obvious red shift,and the characteristic peaks of amide I and amide II had blue shift,which might be that the presence of pollutants in the membrane surface led to the electronic transition of the characteristic groups.
作者 姚萌 方永珍 兰秀娟 洪昱斌 YAO Meng;FANG Yongzhen;LAN Xiujuan;HONG Yubin(Suntar Membrane Technology(Xiamen)Co.,Ltd.,Xiamen 361022,Fujian,China)
出处 《能源研究与管理》 2021年第1期100-103,127,共5页 Energy Research and Management
关键词 焦化废水 中水回用 膜污染 膜清洗 coking wastewater wastewater reuse membrane fouling membrane cleaning
  • 相关文献

参考文献15

二级参考文献112

共引文献354

同被引文献96

引证文献6

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部