摘要
第三代篦冷机升级改造第四代篦冷机是实现节能降耗的重要手段,与产业升级一样是时代发展的需要。文中简述了FLSmidth公司十字棒第四代篦冷机主要技术参数、特点,对主要控制参数、操作原则及故障处理进行了详细说明,改造完成后熟料提产,电耗和煤耗均有所降低,改造效果明显。
Upgrading the Third Generation Grate Cooler to the fourth generation is an important means to achieve energy saving and consumption reduction,as well as industrial upgrading is the need of the Times.This article brief introduced the main technical parameters and characteristics of the 4th generation FLSmidth Cross bar Grate Cooler of FLSmidth including main control parameters,operating principles and fault treatment.It also showed the experience for the cooler retrofit on production increasing,power consumption reduction and coal reduction.
出处
《中国水泥》
CAS
2021年第3期106-109,共4页
China Cement
关键词
第四代篦冷机
十字棒
重要参数
操作原则
the Fourth Generation Grate Cooler
Cross Bar
important parameters
operating principles