研究了火灾自动报警系统新增的专项系统控制器与消防控制室图形显示装置之间、与传统的控制器之间的数据交换问题。为了满足GB 50116—2013《火灾自动报警系统设计规范》的要求,提出了市场上相关产品的改进措施,为消防管理部门及相关产品生产厂家提供参考和借鉴。
This paper studies the data exchange between the newly increased special system controller in the automatic fire alarm system and the graphic display device in the fire control room,as well as the data exchange between the newly increased special system controller and the traditional controller.In order to meet the requirements of standard GB 50116—2013《Code for design of automatic fire alarm system》,the improvement measures are put forward for the relevant products in the market,which may provide reference for the fire management department and the relevant product manufacturers.