摘要
结合阿联酋ABMC 10 000t/d水泥熟料生产线的工程设计实例,通过计算和对比,详细介绍了重油油罐区的消防冷却水系统的设计,包括规范的采用、冷却方式的选择、冷却水量的确定方法。
Based on the design practice of ABMC 10000t/d clinker cement production line in United Arab Emirates,the author introduces in detail the design of fire protection system of Heavy Fuel Oil(HFO)tank farm by calculation and comparison,including the adoption of codes and standards,the selection of cooling mode,a method of determining cooling water quantity.
作者
秦江江
徐梦溪
QIN Jiangjiang;XU Mengxi(Si noma Overseas Engineering Co.,Ltd.,Beijing 100037,China)
出处
《水泥技术》
2021年第2期76-79,共4页
Cement Technology
关键词
油罐区
固定式消防冷却水系统
冷却水量
oil tank farm
fixed fire cooling water system
cooling water quantity