Toric IOL植入术与PCRI联合传统IOL植入术矫正白内障患者角膜散光的Meta分析 被引量:3

Toric Intraocular Lens Implantation and Traditional IOL Implantation Combined with Peripheral Corneal Relaxing Incisions in the Correction of Age-Related Cataract with Corneal Astigmatism: A Meta-Analysis
原文传递
导出
摘要 目的:系统评价Toric人工晶状体(Toric IOL)植入术与传统IOL植入联合角膜缘松解术(PCRI)在矫正年龄相关性白内障患者合并≤3 D角膜散光的有效性、安全性以及对视功能的影响。方法:循证医学研究。采用Cochrane系统评价方法,计算机检索PubMed、EMBASE、Cochrane图书馆、Clinicalkey、Web of Science、中国知网、中国万方、中国维普数据库等,搜集有关白内障合并角膜散光及其治疗措施的相关文章,由2位评价者独立进行文献检索、文献筛选及质量评价,将术后裸眼远视力(UCDVA)、散光矫正量、术后残余散光、对比敏感度等方面进行比较,视力采用最小分辨角对数视力表(LogMAR)的形式进行记录。采用RevMan软件(Ver 5.3)对纳入文献进行Meta分析。结果:共纳入8项随机对照研究,包含白内障患者352例(510眼)。Meta分析结果显示:与传统IOL植入联合PCRI(对照组)相比,Toric IOL矫正年龄相关性白内障合并≤3 D的角膜散光在术后3、6个月UCDVA的更好[均数差(MD)=-0.04,95%CI:-0.07~-0.01,P=0.005];植入Toric IOL组手术散光矫正量大于对照组[MD=0.56,95%CI:0.36~0.76,P<0.001;标准均数差(SMD)=0.94,95%CI:0.47~1.40,P<0.001];植入Toric IOL组术后1个月残余散光度数(MD=-0.13,95%CI:-0.21~-0.04,P=0.003;SMD=-0.34,95%CI:-0.59~-0.10,P=0.007)及术后3、6个月残余散光度数(MD=-0.30,95%CI:-0.51~-0.10,P=0.004;SMD=-0.84,95%CI:-1.42~-0.25,P=0.005)均低于对照组;植入Toric IOL组术后3个月对比敏感度与对照组差异无统计学意义(MD=-0.01,95%CI:-0.08~0.11,P=0.77)。结论:与传统IOL植入联合PCRI相比,Toric IOL植入矫正白内障患者合并≤3 D的角膜散光效果更好。同时,Toric IOL在提高患者术后视力上略具优势,但其临床意义可能不大。二者在术后视功能及视觉相关生活质量方面无明显差异。 Objective:To systematically evaluate by meta-analysis the effectiveness,safety and visual function of toric intraocular lens(IOL)implantation and traditional IOL implantation combined with peripheral corneal relaxing incisions(PCRI)in the correction of age-related cataract with≤3 diopters(D)of corneal astigmatism.Methods:In this evidence-based medical research.PubMed,EMBASE,Cochrane library,Clinicalkey,Web of Science,CNKI,Wanfang,and VIP databases were searched for studies investigating the effect of the toric IOL in the treatment of cataract and corneal astigmatism.Meta-analysis was performed using RevMan 5.3 software to analyze the uncorrected distance visual acuity(UCDVA),residual astigmatism and astigmatism correction between the toric IOL and traditional IOL.Visual acuity was recorded in the form of the LogMAR visual acuity chart.Results:A total of 510 eyes of 352 cataract patients in 8 randomized,controlled trials were included.Meta-analysis results showed that:(1)the mean deviation(MD)of postoperative uncorrected distance visual acuity(logMAR UDVA)at 3 and 6 months was better in the toric intraocular lens group;(2)astigmatism correction at 3 and 6 months after implantation was better in the toric IOL group;(3)postoperative residual astigmatism at 1 month and;(4)at 3 and 6 months was lower for the toric intraocular lens;and(5)there was no significant difference in contrast sensitivity between the toric IOL group and the PCRI group at 3 months.The following data analyses support these findings:(1)MD=-0.04(95%CI:-0.07--0.01,P=0.005);(2)MD=0.56(95%CI:0.36-0.76,P<0.001),standard mean deviation(SMD)=0.94(95%CI:0.47-1.40,P<0.001);(3)at one month:MD=-0.13(95%CI:-0.21--0.04,P=0.003),SMD=-0.34(95%CI:-0.59--0.10,P=0.007);(4)at 3 and 6 months:MD=-0.30(95%CI:-0.51--0.10,P=0.004),SMD=-0.84(95%CI:-1.42--0.25,P=0.005);(5)MD=-0.01(95%CI:-0.08-0.11,P=0.77).Conclusions:Toric IOL is superior to traditional IOL implantation combined with PCRI in correcting≤3 D of corneal astigmatism in cataract patients.The toric IOL has a slight advantage in improving UCDVA,but the difference may not be clinically important.So far,there was no significant difference between the toric IOL and traditional IOL implantation combined with PCRI in postoperative visual function and vision-related quality of life.
作者 郭娑 何海龙 夏子尧 王军 Suo Guo;Hailong He;Ziyao Xia;Jun Wang(Beijing Tongren Eye Center,Beijing Tongren Hospital,Capital Medical University,Beijing Key Laboratory of Ophthalmology and Visual Sciences,Beijing 100730,China;Beijing Institute of Ophthalmology,Beijing 100730,China)
出处 《中华眼视光学与视觉科学杂志》 CAS CSCD 2021年第2期134-141,共8页 Chinese Journal Of Optometry Ophthalmology And Visual Science
关键词 白内障 角膜散光 散光人工晶状体 角膜缘松解术 META分析 cataract corneal astigmatism toric intraocular lens peripheral corneal relaxing incisions meta-analysis
  • 相关文献

参考文献6

二级参考文献42

  • 1Amesbury EC, Miller KM. Correction of astigmatism at the time of cataract surgery. Curr Opin Ophthalmol 2009 ;20( 1) : 19-24.
  • 2Gills Jp GJ. Reducing pre-existing astigmatism. Thorofare, NJ, Slack 1998 :53-66.
  • 3Eydelman MB, Drum B, Holladay J, et al . Standardized analyses of correction of astigmatism by laser systems that reshape the cornea. J Refract Surg 2006 ;22( 1) :81-95.
  • 4Behndig A, Montan P, Stenevi U, et al. Aiming for emmetropia after cataract surgery: Swedish National Cataract Register study. J Cataract Refract Surg 2012;38(7) :1181-1186.
  • 5Khan MI, Muhtaseb M. Prevalence of corneal astigmatism in patients having routine cataract surgery at a teaching hospital in the United Kingdom. J Cataract Refract Surg 2011 ;37(10) :1751-1755.
  • 6Liu YC, Chou P, Wojciechowski R, et al. Power vector analysis of refractive, corneal, and internal astigmatism in an elderly Chinese population: the Shihpai Eye Study. Invest Ophthalmol Vis Sci 2011; 52 ( 13) :9651-9657.
  • 7Cristobal JA, Del BM, Ascaso FJ, et al. Effect of limbal relaxing incisions during phacoemulsification surgery based on nomogram review and numerical simulation. Cornea 2009 ;28 (9) : 1042-1049.
  • 8Muller - Jensen K, Fischer P, Siepe U. Limbal relaxing incisions to correct astigmatism in clear corneal cataract surgery. J Refract Surg 1999;15(5) :586-589.
  • 9Bayramlar HH, Daglioglu MC, Borazan M. Limbal relaxing incisions for primary mixed astigmatism and mixed astigmatism after cataract surgery. J Cataract Refract Surg 2003 ; 29 ( 4 ) : 723 - 728.
  • 10Carvalho MJ ,Suzuki SH, Freitas LL, et al. Limbal relaxing incisions to correct corneal astigmatism during phacoemulsification. J Refract Surg 2007 ;23 (5) :499-504.

共引文献50

同被引文献32

引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部