摘要
阐述某电厂660MW超超临界机组#3高加泄漏的检修处理过程、原因分析,包括水侧和气侧温差、负荷变化速度快给高压加热器带来的热冲击,提出建议的应对措施。
This paper describes the maintenance process and cause analysis of the leakage of No.3 high-pressure heater in 660 MW ultra supercritical unit of a power plant, including the temperature difference between water side and gas side, and the thermal impact of rapid load change on the highpressure heater, and puts forward some countermeasures.
作者
彭浩
胡高斌
薛泳泳
陆伟
蒋柯
PENG Hao;HU Gaobin;XUE Yongyong;LU Wei;JIANG Ke(Jiangsu Guoxin Jingjiang Power Generation Co.,Ltd.,Jiangsu 214500,China)
出处
《集成电路应用》
2021年第3期138-139,共2页
Application of IC