摘要
采用常温超声水溶解法溶解工业用三聚氰胺,在波长250 nm处,以水为参比,建立了紫外分光光度法直接测定工业用三聚氰胺含量的方法。三聚氰胺的质量浓度在0.05~1.50 mg/mL内与吸光度呈线性关系,样品测定值(n=6)的相对标准偏差为0.26%;与国家标准《工业用三聚氰胺》(GB/T 9567-2016)中苦味酸法的测定结果基本一致。所提方法适用于工业用三聚氰胺的快速进货验收、中控检测及生产线成品检验等。
Using the room temperature ultrasonic water dissolution method to dissolve industrial melamine, at a wavelength of 250 nm with water as a reference, the ultraviolet spectrophotometric method of directly determine the content of industrial melamine is established. When the mass concentration of melamine is in the range of 0.05-1.50 mg/mL, a linear relationship with absorbance is found, and the relative standard deviation of the measured value of the sample(n=6) is 0.26%;this measurement result is consistent with the measurement result using the picric acid method specified in the national standard "Melamine for industrial use"(GB/T 9567-2016). The proposed method is suitable for many applications, such as rapid incoming inspection and acceptance of industrial melamine, central control inspection and finished product inspection on production lines, etc.
作者
刘高
吴宇
李铭
LIU Gao;WU Yu;LI Ming(Chengdu Product Quality Inspection and Research Institute Co.Ltd.,Chengdu,Sichuan 610100,China;Sichuan Product Quality Supervision,Inspection and Testing Institute,Chengdu,Sichuan 610100,China)
出处
《肥料与健康》
CAS
2021年第2期68-72,共5页
Fertilizer & Health
关键词
紫外分光光度法
三聚氰胺
超声溶解
ultraviolet spectrophotometry
melamine
ultrasonic dissolution