期刊文献+

催化蒸馏塔节能优化研究

Study on energy saving optimization of catalytic distillation column
原文传递
导出
摘要 通过改造,将低品质的蒸汽通过螺杆热泵增压至高品质的0.55MPa蒸汽,增压后的0.55MPa蒸汽可以满足催化蒸馏塔T1601再沸器E1603的热负荷需要,实现了催化蒸馏塔塔底蒸汽的降级节能优化,节约了蒸汽成本,达到了降本增效的目的。 The low quality steam was supercharged to the high quality 0.55 MPa steam through the screw heat pump by the transformation, and the supercharged 0.55 MPa steam could meet the thermal load needs of the catalytic distillation tower T1601 reboiler E1603.It realized the catalytic distillation tower bottom steam degradation optimization, saved steam cost, achieved the purpose of reducing cost and increased efficiency.
作者 高志文 田雪梅 GAO Zhi-wen;TIAN Xue-mei(Hebei Xinxinyuan Energy Co.,Ltd.,Cangzhou 061108,China)
出处 《精细与专用化学品》 CAS 2021年第3期40-41,共2页 Fine and Specialty Chemicals
关键词 热泵 蒸汽 增压 heat pump steam booster