摘要
近年来,北极地区石油勘探开发进度明显加快,市场前景良好。针对北极永久冻土层最低温度达-9℃的超低温以及该地区作业时间宝贵的问题,要求水泥浆体系在负温环境下候凝时间短且24 h有强度发展。通过研发低温胶凝材料C-SE8和缓凝剂H10S,并复配G级油井水泥和其他添加剂,分别用淡水、海水和14%NaCl溶液配制超低温水泥浆体系。评价结果表明,密度为1.50 g/cm3的水泥浆在-10℃下的24 h抗压强度可达3.6 MPa以上,密度为1.90 g/cm3的水泥浆在-10℃下的24 h抗压强度可达6.8 MPa以上;该体系适用温度为-10℃~30℃,浆体具有良好的流变性能,且稠化时间易调整,满足北极永久冻土层固井施工要求。
Petroleum exploration and development in the Arctic area in recent years has been accelerating.Well cementing operation in this area has long been facing with ultra-low temperature(-9℃)and the precious time available for operation;the cement slurry is required to have strength development in 24 hours at temperatures below zero.Using a self-developed low temperature gelling agent C-SE8 and a self-developed retarder H10S,several ultra-low temperature cement slurries were formulated with class G cement and other additives in fresh water,sea water and 14%NaCl solution.Evaluation of the cement slurries showed that a cement slurry of 1.50 g/cm3 had 24 h compressive strength of at least 3.6 MPa at-10℃;another cement slurry of 1.90 g/cm3 had 24 h compressive strength of at least 6.8 MPa at-10℃.The working temperatures of the cement slurries were between-10℃and 30℃.The cement slurries had good rheology,and the thickening time can be easily adjusted,making them suitable for well cementing in arctic permafrost.
作者
张福铭
齐营
陈小华
马小康
崔新森
ZHANG Fuming;QI Ying;CHEN Xiaohua;MA Xiaokang;CUI Xinsen(Oilfield Chemicals R&D Institute,COSL,Yanjiao,Hebei,065201)
出处
《钻井液与完井液》
CAS
北大核心
2020年第6期757-762,共6页
Drilling Fluid & Completion Fluid
基金
中海油田服务股份有限公司公司级项目“永久冻土层固井水泥浆体系研究”(YHB18YF008)。
关键词
超低温
永久冻土层
抗压强度
稠化时间
Ultra-low temperature
Permafrost
Compressive strength
Thickening time