期刊文献+

电感耦合等离子体质谱法测定坚果中Se含量的不确定度评估 被引量:6

Uncertainty evaluation in determination of Se in nuts by inductively coupled plasma mass spectrometry
下载PDF
导出
摘要 目的对电感耦合等离子体质谱法(inductively coupled plasma mass spectrometry,ICP-MS)测定坚果中硒元素含量的不确定度进行评估。方法根据JJF 1059.1—2012《测量不确定度评定与表示》和JJG196—2006《常用玻璃量器》的规定和要求,通过对整个实验过程产生的不确定度分析,建立数学模型,计算食品中硒元素的不确定度。结果对坚果中硒元素进行测定,得到扩展不确定度为0.103mg/kg,测定结果表示为(1.631±0.103)mg/kg。结论整个实验过程中工作曲线引入的不确定度影响较大,因此应注意工作曲线配制、检测的准确性,确保检测结果的可靠。 Objective To evaluate the uncertainty in the determination of selenium in nuts by inductively coupled plasma mass spectrometry(ICP-MS).Methods According to the regulations and requirements of JJF 1059—2012 Evaluation and expression of uncertainty in measurement and JJG 196—2006 Working glass container,the mathematical model was established to calculate the uncertainty of selenium in food through the analysis of the uncertainty in the whole experimental process.Results The expanded uncertainty of selenium in nuts was 0.103 mg/kg,and the result was(1.631±0.103)mg/kg.Conclusion In the whole experiment process,the uncertainty introduced by the working curve has a great influence,so we should pay attention to the accuracy of the working curve preparation and detection to ensure the reliability of the detection results.
作者 赵晨曦 付志斌 高佳 任贝贝 常凤启 ZHAO Chen-Xi;FU Zhi-Bin;GAO Jia;REN Bei-Bei;CHANG Feng-Qi(Hebei Provincial Center for Disease Control and Prevention,Shijiazhuang 050021,China)
出处 《食品安全质量检测学报》 CAS 北大核心 2021年第5期1677-1681,共5页 Journal of Food Safety and Quality
基金 河北省卫健委跟踪项目(GL2018085)。
关键词 电感耦合等离子体质谱法 坚果 不确定度 inductively coupled plasma mass spectrometry nut Se uncertainty
  • 相关文献

参考文献4

二级参考文献36

共引文献100

同被引文献71

引证文献6

二级引证文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部