摘要 目的:探讨低管电压、低对比剂剂量、低流速注射扫描方案行头颈CTA可行性。方法:随机抽取2019年1月—2020年6月在我院进行头颈部CTA检查的受检者120例,随机分为A组60例,管电压100 kVp、对比剂剂量0.8mL/kg、注射流速4.5mL/s;B组60例,管电压80 kVp、对比剂剂量0.6 mL/kg、注射流速3.5 mL/s。两组均用对比剂碘海醇(350 mgI/mL)。比较两组头颈部血管内CT值、噪声(SD)、CNR、SNR、图像质量评分、CTDIvol、DLP,评价其图像质量及辐射剂量。结果:B组图像SNR、CNR较A组略低,两组不具有统计学差异(P>0.05);B组辐射剂量较A组明显降低,CTDIvol、DLP分别降低约49.4%、52.6%,B组碘摄入量较A组明显降低,降低约27.8%,两组CTDIvol、DLP、碘摄入量差异具有统计学意义(P<0.05)。结论:低管电压、低对比剂剂量及低流速注射在头颈部CTA检查中是可行的,图像质量能完全满足临床诊断需要,而且辐射剂量、碘摄入量明显降低。
作者 汤振华
出处 《影像研究与医学应用》 2021年第5期48-49,共2页 Journal of Imaging Research and Medical Applications
  • 相关文献

参考文献2

二级参考文献24

  • 1Mehran R,Aymong E D,Nikolsky E,et al. A simple risk score for prediction of contrast-induced nephropathy after percutaneous coro- nary interventiong: development and initial validation [ J ]. J Am Coll Cardio1,2004,44 (7) : 1393 - 9.
  • 2Huda W, He W. Estimating cancer risks to adults undergoing body CT examinations[J]. Radiat Prot Dosimetry, 2012 ,150(2):168-l79.
  • 36ervaise A, Osemont B, Lecocq S, et al. CT image quality improvement using Adaptive Iterative Dose Reduction with wide-volume acquisition on 320- detector CT[J].Eur Radiol, 2012 ,22 (2): 295-301.
  • 4IFeuchtner GM, Jodocy D, Klauser A, et al. Radiation dose reduction by using 100- kV tube voltage in cardiac 64- slice computed tomography: a comparative study[J].Eur J Radiol, 2010 ,75(1):e51-6.
  • 5Xia W, Wu JT, gin XR, et al. CT angiography of the neck: value of contrast medium dose reduction with low tube voltage and high tube current in a 64- detector row CT[J].Clin Radiol, 2014,69(4):e183-9.
  • 6Yamada Y, Jinzaki M, Hosokawa T, et al. Dose reduction in chest CT: comparison of the adaptive iterative dose reduction 3D, adaptive iterative dose reduction, and filtered back projection reconstruction techniques[J].Eur J Radiol, 2012,81(12):4185-4195.
  • 7Voo RE, Park EA, Lee W, et al. Image quality of adaptive iterative dose reduction 3D of coronary CT angiography of 640-slice CT: comparison with filtered back- projection[J].Int J Cardiovasc imaging, 2013,29(3):669-676.
  • 8Lee S, Yoon SW, Yoo SM, et il. Comparison of image quality ind radiation dose between :ombined automatic tube :urrent modulation and fixed :ube current technique in Cr ,f abdomen and pelvis[J].Acta adiol, 2011,52(10):1101-1106.
  • 9Van der Molen AJ, Joemai RM, Geleijns J. Performance of longitudinal and volumetric tube current modulation in a 64-slice CT with different choices of acquisition and reconstruction parameters[J]. Phys Med, 2012 ,28(4):319-326.
  • 10Lee He, Chang JG, Yen HN, et al. Ionic contrast mediainduced more apoptosis in diabetic kidney than nonionic contrast media[J].J Nephrol, 2011 ,24(3): 376-380.

共引文献22

同被引文献15

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部