期刊文献+

Trabeculectomy with Ologen implant versus perfluoropropane gas bubble for open angle glaucoma in pseudophakic eyes 被引量:1

下载PDF
导出
摘要 AIM:To evaluate the safety and efficacy of augmented trabeculotomy with Ologen versus perfluoropropane in management of pseudophakic glaucoma.METHODS:This is a comparative randomized study included 57 pseudophakic eyes of 57 patients with medically uncontrolled open angle glaucoma(OAG).Twentynine patients were allocated in group I(trabeculectomy with Ologen;trab-ologen group),while 28 patients were assigned in group II(trabeculectomy with perfluoropropane gas bubble;trab-C3 F8 gas bubble group).RESULTS:The intraocular pressure(IOP)was significantly reduced in both study groups at all postoperative follow up intervals(1 wk,3,6,12,18,24,30 and 36 mo,P<0.001).The differences between the mean IOP values of both groups remained statistically insignificance during the early 12 months of follow up.However,the trab-ologen group achieved a statistically significant reduction over the trab-C3 F8 gas bubble group during the last 24 months of follow up.CONCLUSION:Augmentation of trabeculectomy with either Ologen implant or perfluoropropane gas bubble are associated with strict long term IOP control and evident safety in medically-uncontrolled pseudophakic eyes with OAG.
出处 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2021年第4期510-516,共7页 国际眼科杂志(英文版)