针对联合电解催化交换工艺中的氢气中的含氚水蒸气排放进行研究,在对比分析了两种不同的氢气冷凝方案的基础上,提出了“双冷凝器”的工艺优化设计方案,并分析了“双冷凝器”方案的运行模式。
In this work,the process design of hydrogen vent scheme was illustrated based on combined electrolysis and catalytic exchange system.Two schemes were analyzed firstly,and then“Bi-Condenser”scheme was provided to obtain an optimized design.In addition,the running model was detailed shown in this study.
作者
吴栋
尹玉国
阮皓
胡石林
Wu Dong;Yin Yuguo;Ruan Hao;Hu Shilin(China Institute of Atomic Energy,Beijing 102413,China)
出处
《山东化工》
CAS
2021年第7期165-166,共2页
Shandong Chemical Industry
关键词
联合电解催化交换
冷凝器
氢气排放
combined electrolysis and catalytic exchange
condenser
hydrogen vent