期刊文献+

血液细菌培养仪校准方法及结果分析 被引量:2

Calibration Method and Result Analysis of Blood Culture Apparatus
下载PDF
导出
摘要 温度是血液细菌培养仪的关键参数,控温不准确可能导致血液细菌培养仪报告结果不准确,深入研究血液细菌培养仪校准方法势在必行。本文针对血液细菌培养仪的结构和校准需求,对测温标准器、布点、校准参数进行了实验设计,并在此基础上制定了JJF(川)171-2020《血液细菌培养仪校准规范》。能够客观、准确、全面、系统地评价血液细菌培养仪孵育模块的温场,有助于确保血液细菌培养仪的培养结果可靠性。 Temperature is a key parameter of blood bacterial culture instrument.Inaccurate temperature control may lead to inaccurate report results of blood bacterial culture instrument.Therefore, it is imperative to further study the calibration method of blood bacterial culture instrument.In this paper, according to the structure and calibration requirements of blood bacterial culture instrument, the temperature measuring standard, distribution point, calibration parameters were designed, and on this basis, the JJF(CHUAN)171-2020 " Calibration Specification of Blood Culture Device " was formulated.The temperature field of incubation module of blood bacterial culture instrument can be evaluated objectively, accurately, comprehensively and systematically, which is helpful to ensure the reliability of the culture results of blood bacterial culture instrument.
作者 朱育红 祝天宇 易高军 陈鹏 李征 周选超 张文媛 ZHU Yuhong;ZHU Tianyu;YI Gaojun;CHEN Peng;LI Zheng;ZHOU Xuanchao;ZHANG Wenyuan
出处 《计量与测试技术》 2021年第4期1-3,共3页 Metrology & Measurement Technique
关键词 血培养 血培养仪 温度 校准 blood culture blood culture apparatus temperature the calibration
  • 相关文献

参考文献2

二级参考文献11

  • 1Breeher ME, Hay SN, Rothenberg SJ. Monitoring of apheresis platelet bacterial contamination with an automated liquid culture system : a university experience. Transfusion, 2003;43:974 -978
  • 2AuBuchon JP, Cooper LK, Leach MF, et al. Experience with universal bacterial culturing to detect contamination of apheresis platelet units in a hospital transfusion service. Transfusion, 2002 ;42:855 - 861
  • 3Brecher ME, Hay SN, Rothenberg SJ. Validation of BacT/ALERT plastic culture bottles for use in testing of whole-blood-derived leukoreduced platelet-rich-plasma-derived platelets. Transfusion, 2004; 44:1174 - 1178
  • 4国家技术监督局.献血者健康检查要求.国家标准GB18467-2001
  • 5Brecher ME, Hay SN, Rothenberg SJ. Evaluation of a new generation of plastic culture bottles with an automated microbial detection system for nine common contaminating organisms found in PLT components. Transfusion, 2004 ;44:359 - 363
  • 6McDonald CP, Rogers A, Cox M, et al. Evaluation of the 3D BacT/ ALERT automated culture system for the detection of microbial contamination of platelet concentrates, Transfus Meal, 2002 ; 12 : 303 - 309
  • 7Brecher ME, Holland PV, Pineda AA, et al. Growth of bacteria in inoculated platelets : implications for bacteria detection and the extension of platelet storage. Transfusion, 2000 ; 40 : 1308 - 1312
  • 8方桂珍,郑传权.贝朗Dialog血液透析机的定标与校准[J].中国医疗设备,2012,27(4):121-122. 被引量:4
  • 9周胜利,沈柏钧,阎文瑛,旭日,潘杰,马秀峰,宋道刚.山东脐血库3000份脐带血处理保存的操作程序[J].中国实验血液学杂志,2001,9(2):153-159. 被引量:9
  • 10朱美玲,陈汝光,奚永志,胡燕芬,欧阳玲,张健,黄建国.脐血采集和分离过程中病原微生物污染概率的研究[J].中国实验血液学杂志,2002,10(4):355-358. 被引量:3