摘要
一般采用经典的EDTA络合滴定法测定水体钙镁总硬度。此外还有火焰原子吸收法和市售总硬度快速测试盒。本文验证分析这三种方法的优缺点,结果表明,火焰原子吸收法最适合污水实验室使用。
Generally,the total hardness of calcium and magnesium in water is determined by EDTA complexometric titration.In addition,there are flame atomic absorption method and commercial quick test box for total hardness.In this paper,the advantages and disadvantages of these three methods are verified and analyzed.The results show that the flame atomic absorption method is most suitable for the determination of total hardness in Laboratory of sewage treatment plant.
作者
叶小园
Ye Xiaoyuan(Laboratory,Dongguan Taijing Environmental Protection Technology Co.,Ltd.,Dongguan 523999,China)
出处
《广东化工》
CAS
2021年第3期186-187,共2页
Guangdong Chemical Industry
关键词
总硬度
原子吸收分光光度法
EDTA滴定法
total hardness
atomic absorption spectrophotometric method
EDTA titrimetric method