电感耦合等离子体质谱法测定涤纶长丝中的可萃取锑 被引量:1

Determination of Extractable Antimony in Polyester Filament by Inductively Coupled Plasma Mass Spectrometr
下载PDF
导出
摘要 以酸性汗液为萃取剂,基于电感耦合等离子体质谱(ICP-MS)法,建立了一种快速、准确测定涤纶长丝中可萃取重金属锑含量的方法。该方法检出限低达0.025μg/L;在锑浓度为(2.0~200.0)μg/L范围内线性关系良好,R2大于0.999;2.0,4.0,100.0低中高三个浓度的加标回收率在(90~115)%,准确度良好;RSD=1.1%,具有较好的精密度。 A rapid and accurate method for the determination of extractable heavy metal antimony in polyester filament was developed based on inductively coupled plasma mass spectrometry(ICP-MS) with acid sweat as extractant. The detection limit of the method is as low as 0.025 μg/L;the linear relationship is good in the range of antimony concentration(2.0~200.0) μg/L with R2 greater than 0.999;the recovery rate of standard addition of 2.0, 4.0, 100.0 μg/L are in the range of(90~115)%, showing good accuracy;RSD=1.1 %, indicating good precision.
作者 阮瑜迪 樊灵杰 董岳龙 叶琼 王芬 Ruan Yudi;Fan Lingjie;Dong Yuelong;Ye Qiong;Wang Fen(Shaoxing Testing Institute of Quality and Technical Supervision,Shaoxing 312366;Shaoxing Municipal Party committee of the Communist Youth League,Shaoxing 312000;Zhejiang Supor Pharmaceuticals Co.,Ltd.,Shaoxing 312000,China)
出处 《广东化工》 CAS 2021年第5期202-203,共2页 Guangdong Chemical Industry
关键词 涤纶长丝 ICP-MS Antimony Polyester Filament ICP-MS