期刊文献+

秦二厂SEC反冲洗泵的运行现状及分析

下载PDF
导出
摘要 由于杭州湾海水泥沙含量较高,对泵水力部件具有较大的冲蚀作用,秦山第二核电厂SEC反冲洗泵在连续运行约6个月,就需要对其进行解体检修,更换叶轮、泵壳、泵盖等部件。但在实际运行过程中,往往在未到达定期检修前SEC反冲洗泵便出现故障。论文从运行的角度通过在实际运行中出现的一些常见故障和与技改泵的对比,对秦二厂SEC反冲洗泵的运行现状进行分析和建议。 Because of the high sediment content of seawater in Hangzhou Bay and hydraulic parts of the pump has a greater role in the erosion and Qinshan Phase II nuclear power plant sec anti flushing pump in continuous operation for about six months,you need the for overhaul and replacement of the impeller,pump shell and the pump cover and parts.But in the actual operation of the process,often in the absence of regular maintenance before the SEC anti flushing pump will be a failure.In this paper,from the perspective of operation through the actual operation of a number of common failures and the comparison with the technical transformation,the operation of the SEC anti flush pump in Qin two plant is analyzed and suggestions.
作者 于健
出处 《科技视界》 2021年第10期124-126,共3页 Science & Technology Vision
关键词 SEC反冲洗泵 运行现状 分析 SEC backwash pump Operation status Analysis
  • 相关文献