摘要
耐寒测试机库作为一种特殊的高大空间,其供暖形式一直是暖通空调设计领域的难点。结合了数种飞机维修及测试机库的常用供暖形式,通过分析其各自的优缺点,提出"强制对流供暖"更适合作为耐寒测试机库的供暖形式。通过计算流体力学方法得出侧送风双层暖风机供暖形式供暖效果好,能源消耗低,是本机库供暖形式的最优解决方案,也为其它机库的设计提供参考。
The attendant hangar is a kind of high space building.The heating method for a attendant hangar is the key point for a HVAC design.By summarizing common heating methods and analyzing the advantages and disadvantages of each heating system,we found that the forced-convection heating is the best heating method for this attendant hangar.By adopting the computational fluid dynamics method,the horizon warm air heating is a better way of the forced-convection heating.It also provides reference to for the design of other attendant hangars.
作者
皮英俊
杨晋
Pi Yingjun;Yang Jin(Tongji Architectural Design(Group)Co.,Ltd,Shanghai,200092;Qingdao Hisense Hitachi Air-conditioning Marketing Co.,Ltd,Shanghai,266590)
出处
《制冷与空调(四川)》
2021年第2期258-262,284,共6页
Refrigeration and Air Conditioning
关键词
维修机库
供暖形式
强制对流供暖
数值模拟
attendant hangars
heating methods
forced-convection heating