期刊文献+

Bone Fracture Reduction Surgery-aimed Bone Connection Robotic Hand

原文传递
导出
摘要 Bone connection with robot is an important topic in the research of robot assisted fracture reduction surgery.With the method to achieve bone-robot connection in current robots,requirements on reliability and low trauma can not be satisfied at the same time.In this paper,the design,manufacturing,and experiments of a novel Bone Connection Robotic Hand(BCRH)with variable stiffness capability are carried out through the bionics research on human hand and the principle of particle jamming.BCRH’s variable stiffness characteristic is a special connection between“hard connection”and“soft connection”,which is different from the existing researches.It maximizes the reliability of bone-robot connection while minimizes trauma,meets the axial load requirement in clinical practice,and effectively shortens the operating time to less than 40 s(for mode 1)or 2 min(for mode 2).Meanwhile,a theoretical analysis of bone-robot connection failure based on particle jamming is carried out to provide references for the research in this paper and other related studies.
出处 《Journal of Bionic Engineering》 SCIE EI CSCD 2021年第2期333-345,共13页 仿生工程学报(英文版)
基金 This research was supported by the National Natural Science Foundation of China(Grant Nos.51975070,62003060 and 52075051) the National Key Research and Development Program of China(Grant No.2020YFB1313000).
  • 相关文献

参考文献3

二级参考文献16

  • 1Lanfranco AR,Castellanos AE,Desai JP,et al.Robotic surgery-a current perspective.Ann Surg,2004,239:309-320.
  • 2Coetzee J,Van der Merwe E.Exposure of surgeons-in-training to radiation during intramedullary fixation of femoral shaft fractures.S Afr Med J,1992,81:312-314.
  • 3Muchs M,Schmid A,Eiteljrge T,et al.Exposure of the surgeon to radiation during surgery.Int Orthop (SICOT),1997,22:153-156.
  • 4Sanders R,Koval KJ,Pasquale TD,et al.Exposure of the orthopaedic surgeon to radiation.J Bone Joint Surg Am,1993,75:326-330.
  • 5Levin P,Schoen R,Browner B.Radiation exposure to the surgeon during closed interlocking intramedullary nailing.J Bone Joint Surg Am,1987,68:761-766.
  • 6Sugarman ID,Adam I,Bunker TD.Radiation dosage during AO locking femoral nailing.Injury,1998,19:336-338.
  • 7Noordeen MH,Shergill N,Twyman RS,et al.Hazard of ionizing radiation to trauma surgeons:reducing the risk.Injury,1993,24:562-564.
  • 8Mahaisavariya B,Laupattarakasem W,Kosuwon W.An aiming device for distal locking in closed locked femoral nailing.Injury 1992,23:143-144.
  • 9Skjeladal S,Backe S.Interlocking medullary nails-radiation doses in distal targeting.Arch Orthop Trauma Surg,1987,106:179-181.
  • 10Schep NW,Broeders IA,Chr MJ.Computer assisted orthopaedic and trauma surgery,state of the art and future perspectives.Injury,2003,34:299-306.

共引文献18

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部