摘要 钛管泄漏(凝结水水质)直接影响机组二回路水质和运行安全可靠性。通过对某核电厂参考电站凝汽器钛管泄漏的原因分析,对“华龙一号”凝汽器从管板间距、钛管与支撑板配合间隙、迎流面厚壁管布置、喉部布置、旁扩布置及减压布置、管束布置等结构改进与参考电站进行了对比说明和核算,结果表明,该结构能够有效避免因振动问题导致的大面积钛管泄漏,并根据AP-913的理念及相关机组凝汽器可靠性管理现状提出了“华龙一号”凝汽器预防性管理思路和建议。 Leakage from titanium pipe(condensate water quality)directly affects the water quality of the secondary loop and operation safety.This thesis analysis the reason of the reference station condenser titanium pipe leakage.Based on the structure improvement of space between pipe and plate,fitting space between titanium pipe and supporting plate,arrangement of thick wall pipe on the inflow face,throat arrangement,expansion and decompression arrangement,tube bundle arrangement,this thesis compare HPR1000 condenser with the reference station condenser,the result indicate that structure of HPR1000 condenser can effectively avoid large area titanium pipe leakage which caused by vibration peoblem.This thesis also learned from AP-913 idea and the status of preventive management in the station condenser,it raises the preventive management idea and advice to the HPR1000.
作者 于新娜 江鸿 YU Xin-na;JIANG Hong(Fujian Fuqing Nuclear Power Company Limited,Fuqing 350318,China)
出处 《汽轮机技术》 北大核心 2021年第2期147-150,共4页 Turbine Technology
关键词 凝汽器 钛管 泄漏 预防性管理 condenser titaniumpipe leakage preventive management
  • 相关文献

参考文献5

二级参考文献27

  • 1杨振国.核电装置换热器的失效分析及其解决对策[J].金属热处理,2007,32(z1):28-35. 被引量:6
  • 2过邦辅.坎贝尔骨科手术大全[M].上海:上海远东出版社,1991.996-1004.
  • 3GB/T 12145-2008.火力发电机组及蒸汽动力设备水汽质量[S].
  • 4马元障.关节骨折一经皮橇拨复位内固定和缝合[M].上海科技出版社,1982.1770.
  • 5李世民 党耕町.临床骨科学[M].天津:天津科学技术出版社,1996.357-357.
  • 6GB/T 3620.1-2007.钛及钛合金牌号和化学成分[S]..2007
  • 7Yun-Song Gu,Yi Gong,Zhen-Guo Yang.Hydrogen Embrittlement on High-Speed Stainless Steel Belts Used for Tin Plating Chip Lead Frame[J].Journal of Failure Analysis and Prevention.2010(5)
  • 8Yang Z G,Gong Y,Yuan J Z.Failure analysis of leakage on titanium tubes within heat exchangers in anuclear power plant.Part I:Electrochemical corrosion[].Materials and Corrosion.2012
  • 9Yang Z G,Gong Y,Yuan J Z.Failure analysis of leakage on titanium tubes within heat exchangers in anuclear power plant.Part II:Mechanical degradation[].Materials and Corrosion.2012
  • 10Wang Y F,Yang Z G.Finite element model of erosive wear on ductile and brittle materials[].Wear.2008

共引文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部