期刊文献+

多层螺旋CT血管成像技术在主动脉夹层动脉瘤诊断中的价值 被引量:4

Value of multi-slice spiral CT angiography in the diagnosis of aortic dissecting aneurysm
下载PDF
导出
摘要 目的探索多层螺旋CT血管成像技术在主动脉夹层动脉瘤诊断中的价值。方法选取50例疑似主动脉夹层动脉瘤患者作为研究对象,均进行多层螺旋CT血管成像、数字血管造影检查。结果多层螺旋CT血管成像技术诊断主动脉夹层动脉瘤的灵敏度、特异度、漏诊率、误诊率分别为92.68%、88.89%、7.32%、11.11%。多层螺旋CT血管成像技术与数字血管造影在判断管壁钙化率、腔内血栓率、破口数量方面无显著差异(P>0.05)。多层螺旋CT血管成像技术诊断主动脉夹层动脉瘤分型、病变累及区域的准确率均为92.68%。结论应用多层螺旋CT血管成像技术评估主动脉夹层动脉瘤能更好反映病变累及区域及病情发展程度,值得推广。 Objective To explore the value of multi-slice spiral CT angiography in the diagnosis of aortic dissecting aneurysm.Methods Fifty patients with suspected aortic dissecting aneurysm were selected as the research objects,and all of them were examined by multi-slice spiral CT angiography and digital angiography.Results The sensitivity,specificity,missed diagnosis rate and misdiagnosis rate of multi-slice spiral CT angiography in the diagnosis of aortic dissecting aneurysm were 92.68%,88.89%,7.32%and 11.11%respectively.There were no significant differences in judging the wall calcification rate,intraluminal thrombosis rate and the number of breaks between multi-slice spiral CT angiography and digital angiography(P>0.05).The accuracy of multi-slice spiral CT angiography in the diagnosis of aortic dissecting aneurysms classification and lesion involved area were 92.68%.Conclusion Multi-slice spiral CT angiography applied in the evaluation of aortic dissecting aneurysm can better reflect the lesion involved area and the degree of disease development,which is worthy of promotion.
作者 夏军 张博 XIA Jun;ZHANG Bo(Xianyang Central Hospital,Xianyang 712000,China)
机构地区 咸阳市中心医院
出处 《临床医学研究与实践》 2021年第14期121-123,共3页 Clinical Research and Practice
关键词 多层螺旋CT 血管成像 主动脉夹层动脉瘤 multi-slice spiral CT angiography aortic dissecting aneurysm
  • 相关文献

参考文献8

二级参考文献53

共引文献52

同被引文献28

引证文献4

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部