高精低噪氧化锆氧量检测技术设计 被引量:1

Design of High Precision and Low Noise Zirconia Oxygen Detection Technology
原文传递
导出
摘要 提出了一种高精低噪声氧量检测系统设计,利用氧化锆传感器测量氧量,结合差分微弱信号调理设计、模糊-PID复合算法实现恒温控制和传感器温度误差补偿,实现锆池电动势标准差0.01mV以内,氧量测量精度0.5%FS以内,测量范围0-25%,温度控制精度±1℃,内阻测量精度优于0.05%,量程10KΩ。 This study designs a high precision and low noise oxygen detection system,using zirconia oxygen sensor and combining with difference weak signal conditioning design and complex fuzzy-PID algorithm to realize the temperature control and temperature sensor error compensation,it also realizes zirconium pool emf standard deviation less than 0.01 mV,oxygen measurement accuracy within 0.5%FS,measurement range 0-25%,plus or minus 1℃,the temperature control precision internal resistance measurement precision is better than 0.05%,10 kΩrange.
作者 李万军 申同强 常寿兵 王鹏 Li Wanjun;Shen Tongqiang;Chang Shoubin;Wang Peng(School of Electronic and Control Engineering,North China Institute of Aerospace Engineering;Walsn Measurement and Control Technology〈Hebei〉Co.LTD,Langfang 065000,China)
出处 《北华航天工业学院学报》 CAS 2021年第2期5-7,共3页 Journal of North China Institute of Aerospace Engineering
基金 北华航天工业学院基金项目(KY-2018-21) 廊坊市科技支撑计划项目(2017011003) 北华航天工业学院教学研究与教学改革项目(JY-2020-22)。
关键词 氧化锆 氧量 数据采集 信号处理 zirconia oxygen data acquisition signal processing
  • 相关文献

参考文献3

二级参考文献8

  • 1李俊华,张仲生,韩月奇.封闭采样式高温氧化锆氧分析仪的试验及应用[J].原子能科学技术,1997,31(2):173-176. 被引量:1
  • 2JJG945-1999《原电池氧分析器》.中国计量出版社.
  • 3JJG662-2005《顺磁式氧分析器》.中国计量出版社.
  • 4JJG535-2004《氧化锆氧分析器》.中国计量出版社.
  • 5JJG365-2008《电化学氧测定仪》.中国计量出版社.
  • 6崔熙中.北京久兴隆分析仪器有限公司《气体中氧测量仪》技术文件.2007.12.
  • 7JJG945-2009《微量氧分析器》修订版(待颁布).
  • 8鲁盛会,向蓝翔,李金英,周欣燕,石磊,沙顺萍.ZrO_2基氧传感器电极用Pt浆的研制[J].贵金属,2012,33(4):48-52. 被引量:2

共引文献11

同被引文献11

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部