期刊文献+

全身成像三维量化评价左心室收缩功能的可行性研究

Study on feasibility of general imaging 3-dimensional quantification in assessing left ventricular systolic function
下载PDF
导出
摘要 目的探讨全身成像三维量化(GI3DQ)评价左心室收缩功能的可行性。方法选取45例患者,采用二维Simpson′s法(以下简称2D法)测量左心室舒张末期容积(EDV)和收缩末期容积(ESV),每搏输出量(SV),得出左心室射血分数(LVEF);用实时三维超声心动图(RT-3DE)采集心尖四腔心全容积图像,导入QLABadv,测量EDV和ESV,得出LVEF;将实时三维心尖四腔心全容积图像导入GI3DQ三维图像工作站脱机测量EDV和ESV,得出LVEF。结果GI3DQ与2D法评价左心室功能参数测值,EDV、ESV、SV、LVEF比较差异均无统计学意义(P>0.05),二者评价LVEF相关性较好(r=0.870),两种方法进行一致性分析差异无统计学意义(P>0.05);GI3DQ与RT-3DE评价左心室功能参数测值,EDV、SV比较差异均无统计学意义(P>0.05),但二者ESV、LVEF比较差异有统计学意义(P<0.05),二者评价LVEF值相关性较好(r=0.920),两种方法进行一致性分析差异无统计学意义(P>0.05)。结论GI3DQ可对左心室收缩功能进行准确的定量评估,为临床评价左心室收缩功能提供了更加准确、简便的方法。 Objective To evaluate the feasibility of general imaging 3-dimensional quantification(GI3DQ)in assessing the left ventricular systolic function.Methods Forty-five patients were selected.The left ventricular end diastolic volume(EDV),end systolic volume(ESV)and stroke volume(SV)were measured by adopting the dimensional Simpson′s method(2D method),and the left ventricular ejection fraction(LVEF)was obtained;the full volume image of apical four chamber heart was collected by using the real-time three-dimensional echocardiography(RT-3DE),by importing QLABadv,EDV and ESV were measured to obtain LVEF;the full volume image of three-dimensional apical four chamber heart was imported into the GI3DQ three-dimensional imaging work station for offline measuring EDV and ESV,and LVEF was obtained.Results The measured values of parameters EDV,ESV,SV and LVEF for evaluating the left ventricular function had no statistically significant difference between the GI3DQ and 2D method(P>0.05),the correlation of both in evaluating LVEF was good(r=0.870),the difference in the consistency analysis had no statistical difference between the two methods(P>0.05);in evaluating the measured values of left ventricular function parameters by GI3DQ and RT-3DE,EDV and SV had no statistically significant difference(P<0.05),but ESV and EF had statistically significant difference betweeen them(P<0.05).The both for evaluating the LVFE value had good correlation(r=0.920),and the difference in the consistency analysis had no statistical significant between the two methods(P>0.05).Conclusion GI3DQ can accurately and quantitatively evaluate the left ventricular systolic function,which provides a more accurate and simple method for clinical evaluation of left ventricular systolic function.
作者 唐海霞 景香香 林凌 钟文津 刘丽莉 TANG Haixia;JING Xiangxiang;LIN Ling;ZHONG Wenjin;LIU Lili(Department of Ultrasound,Hainan Provincial People′s Hospital/Affiliated Hainan Hospital of Hainan Medical University,Haikou,Hainan 570311,China)
出处 《重庆医学》 CAS 2021年第9期1577-1580,1585,共5页 Chongqing medicine
基金 海南省卫生计生普通科研项目(18A200023)。
关键词 全身成像三维量化 超声心动描计术 收缩功能 心室 general imaging 3-dimensional quantification echocardiography systolic function,ventricle,left
  • 相关文献

参考文献3

二级参考文献27

  • 1Bursi F, Enriquez-Sarano M, Nkomo VT, et al. Heart failure and death after myocardial infarction in the community: the emerging role of mitral regurgitation. Circulation, 2005,111 ( 3 ) : 295-301.
  • 2Rosenhek R, Rader F, Klaar U, et al. Outcome of watchfid waiting in asymptomatic severe mitral regurgitation. Circulation,2006, 113 ( 18 ): 2238-2244.
  • 3Laneellotti P, Moura L, Pierard LA, ct al. European association of echocardiography recommendations for the assessment of valvular regurgitation, part 2: mitral and tricuspid regurgitation (native disease ). Eur J Echocardiogr , 2010, 11 (4) : 307-332.
  • 4Marsan NA, Westenberg J J, Ypenburg C, et al. Quantification of functional mitral regurgitation by real time 3D echocardiography: comparison with 3D velocity-encoded cardiac magnetic resonance. JACC Cardiovasc Imaging , 2009,2( 11 ): 1245-1452.
  • 5Marsan NA, Westenberg J J, Roes SD, et al. Three-dimensional echocardiography for the preoperative assessment of patients with left ventricular aneurysm. Ann Thorac Surg , 2011,91 ( 1 ) : 113-121.
  • 6de Agust i n JA, Marcos-Alberca P, Femandez-Golfin C, et al. Direct measurement of proximal isovelocity surface area by single-beat three-dimensional color Doppler echocardiography in mitral regurgitation: a validation study. J Am Soc Echocardiogr,2012,25(8) : 815-823.
  • 7Grayburn PA, Weissmml NJ, Zamorano JL. Quantitation of mitral regurgitation. Circulation, 2012,126 ( 16 ) : 2005-2017.
  • 8Chao K, Moises VA, Shandas R, et al. Influence of the Coanda effect on color Doppler jet area and color encoding. In vitro studies using color Doppler flow mapping. Circulation, 1992,85( 1 ):333-341.
  • 9Shiota T, Sinclair B, Ishii M, et al. Three-dimensional reconstruction of color Doppler flow convergence regions and regurgitant jets: an in vitro quantitative study.J Am Coil Cardiol, 1996,27 (6) : 1511-1518.
  • 10Sugeng L, Weinert L, Lang RM. Real-time 3-dimensional color Doppler flow of mitral and tricuspid regurgitation: feasibility and initial quantitative compm-ison with 2-dimensional methods. J Am Soc Echocardiogr, 2007,20( 9 ) : 1050-1057.

共引文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部