摘要
复合压裂管柱存在油管长度配置不合理,轴向抗拉安全系数过剩的问题。以轴向抗拉安全系数为设计目标,对复合管柱各段油管进行受力分析,推导了各段油管长度的计算公式,揭示了影响各段油管长度的因素。以3700 m长复合管柱为例,优化后的复合压裂管柱各项安全系数满足要求,并且可以减少15%管材使用量。
The composite fracturing string has the problems of unreasonable tubing length configuration and excessive axial tensile safety factor.Taking the axial tensile safety factor as the design goal,the force analysis of each section of the composite string was carried out,the calculation formula of each section of the tubing length was deduced,and the factors affecting the length of each section of the tubing were revealed.Taking the 3700 m long composite pipe string as an example,the safety factors of the optimized composite fracturing string meet the requirements and can reduce the amount of pipe used by 15%.
作者
韩光耀
舒博钊
刘海龙
刘帅
郝丽华
HAN Guangyao;SHU Bozhao;LIU Hailong;LIU Shuai;HAO Lihua(Engineering Technology Research Institute,PetroChina Xinjiang Oilfield Company,Karamay 834000,China)
出处
《石油矿场机械》
CAS
2021年第3期28-31,共4页
Oil Field Equipment
基金
中石油股份公司重大专项“准噶尔盆地致密油储层改造关键技术研究与现场试验”(2019CGCG006)。
关键词
复合管柱
安全系数
优化设计
composite pipe string
safety factor