Performance of insulated FRP-strengthened concrete flexural members under fire conditions

原文传递
导出
摘要 This paper presents the results of fire resistance tests on carbon fiber-reinforced polymer(CFRP)strengthened concrete flexural members,i.e.,T-beams and slabs.The strengthened members were protected with fire insulation and tested under the combined effects of thermal and structural loading.The variables considered in the tests include the applied load level,extent of strengthening,and thickness of the fire insulation applied to the beams and slabs.Furthermore,a previously developed numerical model was validated against the data generated from the fire tests;subsequently,it was utilized to undertake a case study.Results from fire tests and numerical studies indicate that owing to the protection provided by the fire insulation,the insulated CFRP-strengthened beams and slabs can withstand four and three hours of standard fire exposure,respectively,under service load conditions.The insulation layer impedes the temperature rise in the member;therefore,the CFRP-concrete composite action remains active for a longer duration and the steel reinforcement temperature remains below 400°C,which in turn enhances the capacity of the beams and slabs.
出处 《Frontiers of Structural and Civil Engineering》 SCIE EI CSCD 2021年第1期177-193,共17页 结构与土木工程前沿(英文版)
  • 相关文献

参考文献1

二级参考文献17

  • 1卓静,李唐宁,邢世建,周密.一种锚固FRP片材的体外预应力新方法[J].土木工程学报,2007,40(1):15-19. 被引量:21
  • 2高皖扬,胡克旭,陆洲导.FRP结构火灾研究进展与趋势[A]//第四届全国钢结构防火及防腐技术研讨会暨第二届全国结构抗火学术交流会论文集[C].上海,2007:408-422.
  • 3Bisby L. Fire behavior of fiber-reinforced polymer (FRP) reinforced or confined concrete [ D]. Canada: Department of Civil Engineering, Queen' s University ,2003.
  • 4Kodur V K R,Baingo D. Fire resistance of FRP reinforced concrete slabs [ R]. Ottawa: National Research Council of Canada, 1998.
  • 5Gamage J C PH, Wong M B, AI Mahaidi R. Performance of CFRP strengthened concrete members under elevated temperatures [ A ]//Proceedings of the International Symposium on Bond Behavior of FRP in Structures ( BBFS 2005 ) [ C ]. Hong Kong: 2005 International Institute for FRP in Construction ,2005.
  • 6ACI committee 440 Design and construction of externally bonded FRP systems for strengthening concrete structures [ S]. Michigan: American Concrete Institute,2002.
  • 7Bisby L A, Green M F, Kodur V K R. Modeling the behavior of fiber reinforced polymer-confined concrete columns exposed to fire [ J ]. Journal of Composites for Construction, ASCE, 2005, 9(1) :15-24.
  • 8CECS146:2003碳纤维片材加固修复混凝土结构技术规程[S].北京:中国计划出版社,2003.
  • 9高皖扬,陆洲导,胡克旭.FRP加固钢筋混凝土结构防火方法研究[A].李宏男;伊廷华.第二届结构工程新进展国际论坛论文集[C].北京:中国建筑工业出版社,2008.
  • 10Blontrock H, Taerwe L, Vandevelde P. Fire tests on concrete beams strengthened with fibre composites laminates[ A]//Proceedings of the Third International PhD Symposium[ C]. Vienna : Institute of Structural Engineering University of Agricultural Sciences, 2000 : 151-161.