本文通过对R76《非自动衡器》国际建议中衡器对称重传感器的有关要求的研究分析,结合OIML R60《称重传感器》国际建议,研究分析称重传感器参数Y对衡器的影响,以正确理解称重传感器参数Y进而在衡器中正确选择合适的称重传感器,确保衡器的计量性能和长期稳定性。
Based on the analysis of R76"non automatic weighing instrument"international recommendations of weighing instrument symmetrical weight sensor requirements,combined with OIML R60"load cell"international recommendations,this paper study and analyze the influence of load cell parameter Y on the weighing instrument,in order to correctly understand the load cell parameter Y,and then correctly select the appropriate load cell in the weighing instrument,to ensure the weighing performance and long-term stability of the weighing instrument.
出处
《衡器》
2021年第2期26-27,34,共3页
Weighing Instrument
关键词
称重传感器
参数Y
衡器
R76国际建议
R60国际建议
load cell
parameter Y
weighing instrument
R76 International Recommendation
R60 International Recommendation