摘要 针对某发电厂600 MW超临界汽轮发电机严重漏氢问题,分析了机组运行中的异常情况和检修中发现的问题,查明了漏氢的原因,进行了系统调整、技术改造以防止氢气泄漏。采取措施后,发电机本体气密性试验结果表明漏氢量符合要求。 In allusion to a serious hydrogen leakage problem of a 600 MW supercritical steam turbine generator in a power plant,the abnormal situation in unit operation and the problems found in maintenance are analyzed,the causes of hydrogen leakage are found out,system adjustment and technical modification are adopted to prevent hydrogen leakage.After taking the measures,the results of the gas tightness test of the generator body show that the amount of hydrogen leakage meets the requirement.
作者 张振宇 郭业晓 张锦辉 李勇 ZHANG Zhenyu;GUO Yexiao;ZHANG Jinhui;LI Yong(Technology Center of SPIC Henan Electric Power Co.,Ltd.,Zhengzhou 450000,China;SPIC Henan Electric Power Co.,Ltd.Pingdingshan Power Generation Branch,Pingdingshan 467000,China)
出处 《山东电力高等专科学校学报》 2021年第2期41-44,共4页 Journal of Shandong Electric Power College
关键词 发电机 漏氢 轴颈磨损 generator hydrogen leakage journal wear