期刊文献+

600 MW机组凝结水泵变频改造及逻辑优化研究及应用 被引量:2

Research and Application of Frequency Conversion Modification and LogicOptimization of Condensate Pump of 600MW Unit
下载PDF
导出
摘要 凝结水泵是600 MMW火力发电机组重要的6 kV系统厂用辅机。凝泵工频运行时除氧器水位采用水位调整门控制,最大负荷时阀门开度较低;低负荷运行时阀门开度更小,节流损失大,如果将凝结水泵工频改为变频调速控制,运行中需消耗的厂用电量则大大降低。 The condensate pump is an important auxiliary machine for the 6 kV system of the 600 MMW thermal power generating unit.The water level of the deaerator is controlled by a water level adjustment gate when the condensate pump is operating at a power frequency.The valve opening is lower at maximum load;the valve opening is smaller at low load operation and the throttling loss is large.If the power frequency of the condensate pump is changed to a variable frequency control Speed control,the power consumption of the plant during operation is greatly reduced.
作者 蒯凤美 Kuai Feng-mei
出处 《电力系统装备》 2021年第6期73-74,共2页 Electric Power System Equipment
关键词 变频改造 节流损失 逻辑优化 frequency conversion transformation throttling loss logic optimization