期刊文献+

HXD2B型电力机车主变流柜轴隔离原因的研究探讨 被引量:1

Research on causes of shaft isolation in main converter cabinet of HX2B electric locomotive
原文传递
导出
摘要 针对HXD2B型机车运用中或C5修程后发生的典型主变流柜电气及冷却系统故障原因进行分析,结合现场案例进行研究探讨,找出解决问题的方法,降低故障率,确保机车质量持续稳定可靠。 The paper analyzes the causes of the typical electrical and cooling system failures that occur in main converter cabinet of HXD2B B locomotive during the operation or after the C5 repair process. Through research and discussion based on field cases, the methods to solve the problem are found out, which reduce the failure rate and ensure the continuous stability and reliability of locomotive quality.
作者 孙家林 陈闯 徐伟 SUN Jialin;CHEN Chuang;XU Wei(Tangshan Locomotive Depot,China Railway Beijing Bureau Group Co.,Ltd.,Tangshan 063022,China;CRRC Dalian Locomotive Research Institute Co.,Ltd.,Dalian 116021,China)
出处 《铁道机车与动车》 2021年第4期46-48,6,I0004,共5页 Railway Locomotive and Motor Car
关键词 HXD2B型机车 轴隔离 主变流器 故障代码 HXD2B locomotive shaft isolation main converter fault code