期刊文献+

SOP在实际配电网规划中的应用研究 被引量:1

Application of SOP in Actual Distribution Network Planning
下载PDF
导出
摘要 实际配电网在网络参数、联络开关数量、负荷转供能力等方面与标准算例有着明显区别,为解决实际配电网中联络开关和柔性软开关(Soft Ppen Point,SOP)配合供电问题,采用有源配电网柔性软开关规划方法对西部某地区实际算例进行分析,以安装柔性软开关容量、网损以及经济性为目标函数,优化配电网中柔性软开关安装位置和容量,在正常运行时柔性软开关将配电网柔性互联,在故障情况下能提供故障电流,使故障迅速隔离,提高供电可靠性。 The actual distribution network is obviously different from the standard calculation example in terms of the network parameters,the number of contact switches,and the load transfer capacities,etc..In order to solve the problem of matching power supply between the tie switch and soft open point(SOP) in the actual distribution network,an active distribution network SOP planning method is used to analyze an actual example of a certain area in the west.The SOP capacity to be installed,the network loss and the economy are taken as the objective function to optimize the installation position and capacity of SOPs in the distribution network.The SOP not only flexibly interconnects the distribution network during normal operation,but also improves power supply reliability in case of faults by providing fault current and isolating the fault quickly.
作者 龙武 李巍巍 喻松涛 陈夏 方明利 李绍强 LONG Wu;LI Weiwei;YU Songtao;CHEN Xia;FANG Mingli;LI Shaoqiang(Liupanshui Power Supply Bureau,Guizhou Power Grid Co.,Ltd.,Guizhou Liupanshui 553000,China;CSG Electric Power Research Institute,Guangdong Guangzhou 510663,China)
出处 《广西电力》 2021年第2期42-48,共7页 Guangxi Electric Power
基金 国家高技术研究发展计划(863计划)项目(2015AA050103) 六盘水“十四五”配电网规划项目。
关键词 实际配电网 柔性软开关 规划方法 故障电流 actual distribution network soft open point planning method fault current
  • 相关文献

参考文献9

二级参考文献76

共引文献351

同被引文献5

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部