摘要
对横管式初冷器容易出现堵塞和阻力增大的问题,通过对两种不同吹扫方式的实际运行效果进行对比,提出合理的吹扫方法,解决了初冷器堵塞和阻力增大的问题,确保了初冷器的稳定、连续运行。
For cross-tube primary coolers, which are prone to clogging and increasing resistance, by comparing the actual operation effect of two different blowing methods, a reasonable blowing method was proposed to solve the problem of blockage and resistance increase of the primary cooler, ensuring the stable and continuous operation of the primary cooler.
作者
杜建林
DU Jianlin(Shanxi Fulong Coal Chemical Co.,Ltd.,Taiyuan 030000,Shanxi Province)
出处
《氮肥技术》
CAS
2021年第2期17-17,26,共2页
Nitrogenous Fertilizer Technology
关键词
初冷器
阻力
效果
对比
primary cooler
resistance
effect
contrast