摘要
某污水处理厂将管式微孔曝气系统改造成射流式曝气系统。本文对曝气系统改造前后的工艺参数进行了全面分析,结果表明:射流曝气改造后曝气池溶解氧从1.4 mg/L上升到2.9 mg/L,水中溶解氧量明显增加,且气水比与改造前相比下降11%,但改造后二沉池出水COD值、SS值分别较改造前出水COD值高出15.4%、84.9%。终沉池的COD去除能力得到了显著提升,终沉池去除率从29.9%提高到55.3%。
The tubular microporous aeration system was transformed into jet aeration system in a sewage treatment plant.The process operation parameters after the transformation of aeration system were analyzed.The results showed that dissolved oxygen in aeration tank increased from 1.4 mg/L to 2.9 mg/L,dissolved oxygen in water increased significantly,and gas water ratio decreased by 11%compared with that before transformation,but COD value and SS value of effluent from secondary sedimentation tank after transformation were increased.The COD value of effluent was 15.4%and 84.9%higher than that before the reconstruction.COD removal capacity of the final sedimentation tank was significantly improved.Before the transformation,the removal rate of final sedimentation tank was 29.9%.After the transformation,the removal rate of final sedimentation tank was 55.3%.
作者
吴益锋
林建翔
费乐民
潘炯
陈锋
吴祖良
WU Yi-feng;LIN Jian-xiang;FEI Le-min;PAN Jiong;CHEN Feng;WU Zu-liang(Shaoxing Shengxin Shouchuang Sewage Water Treatment Co.,Ltd.,Zhejiang Shengzhou 312400;School of Environmental Science and Engineering,Zhejiang Gongshang University,Zhejiang Hangzhou 310018;School of Environmental and Safety Engineering,Changzhou University,Jiangsu Changzhou 213164,China)
出处
《广州化工》
CAS
2021年第11期92-94,共3页
GuangZhou Chemical Industry
关键词
射流式曝气
曝气池DO
二沉池COD和SS
终沉池COD
污泥
jet aeration
aeration tank DO
secondary sedimentation tank COD and SS
final sedimentation tank COD
sludge