摘要
结合不同地区绿色建筑混合无功补偿的设计要求,以某学校项目为例,提供混合无功补偿设备选择及补偿容量计算的思路,给出混合无功补偿设备中各元器件主要参数的确定过程。
Combined with the design requirements of hybrid reactive power compensation for green buildings in different regions,taking the hybrid reactive power compensation design of a school project as an example,this paper provides the method of hybrid compensation equipment selection and compensation capacity calculation,and the determination process of main parameters of each component in the hybrid compensation equipment are given.
作者
张毓
Zhang Yu(Goa Group of Architects,Hangzhou 310012,China)
出处
《智能建筑电气技术》
2021年第2期60-63,共4页
Electrical Technology of Intelligent Buildings
关键词
绿色建筑
混合无功补偿
设备选择
容量计算
green building
hybrid reactive power compensation
selection of compensation equipment
calculation of compensation capacity