期刊文献+

基于傅里叶红外光谱法测定燃煤电厂烟气中SO_(3)与H_(2)SO_(4)

Measurement of Sulfur Trioxide and Sulfuric Acid in Flue Gas from Coal-Fired Power Plant Via Fourier Infrared Spectroscopy
下载PDF
导出
摘要 基于傅里叶红外光谱法(FTIR)监测燃煤电厂烟气处理流程中的SO_(3)与H_(2)SO_(4)。结果表明,布袋除尘进口、出口和烟囱出口的SO_(3)与H_(2)SO_(4)之和(SO_(3)+H_(2)SO_(4))分别为(29.33±2.30)mg/m^(3)、(25.15±1.63)mg/m^(3)和(12.13±1.26)mg/m^(3);布袋除尘与湿法脱硫对SO_(3)+H_(2)SO_(4)的去除率分别为14.11%与48.38%;控制冷凝法(国标法)测得布袋除尘出口SO_(3)+H_(2)SO_(4)为23.41 mg/m^(3),与FTIR测定结果基本一致。 Sulfur trioxide and sulfuric acid(SO_(3)and H_(2)SO_(4))in flue gas from coal-fired power plants were measured via Fourier infrared spectroscopy(FTIR).The results showed the sum of SO_(3)and H_(2)SO_(4)(SO_(3)+H_(2)SO_(4))in the inlet and outlet of bag filter,chimney outlet were(29.33±2.30)mg/m^(3)、(25.15±1.63)mg/m^(3)and(12.13±1.26)mg/m^(3),respectively.The removal rates of SO_(3)+H_(2)SO_(4)by bag filter and by wet desulphurization were 14.11%and 48.38%,respectively.The concentration of SO_(3)+H_(2)SO_(4)at the outlet of bag filter was 23.41 mg/m^(3)by controlled condensation method,which was consistent with the result via FTIR.
作者 罗威威 沈志刚 LUO Wei-wei;SHEN Zhi-gang(Fujian Boiler and Pressure Vessel Inspection Institute,Fuzhou,Fujian 350008,China;Shanghai Chuanglan Testing Technology Co.,Ltd.,Shanghai 200233,China)
出处 《环境监测管理与技术》 CSCD 2021年第3期57-59,共3页 The Administration and Technique of Environmental Monitoring
基金 中央引导地方科技发展专项基金资助项目(2019L3020) 福建省市场监督管理局科技基金资助项目(FJMS2019019)。
关键词 三氧化硫 烟气 在线监测 傅里叶红外光谱法 燃煤电厂 Sulfur trioxide Flue gas On-line monitoring Fourier infrared spectroscopy Coal-fired power plant
  • 相关文献

参考文献11

二级参考文献145

共引文献126

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部