摘要 在超高层建筑的消防系统设计中,供水方式的不同会对消防系统的可靠性造成影响。本文以兰州地区1栋230 m超高层商业办公综合体建筑为研究对象,通过建立合理的消防可靠性模型,对3种消防供水方案的可靠性进行计算、分析,并研究高位消防水箱、水箱分格设置及混联系统对消防可靠性的影响。结果表明:常高压为主的消防供水系统具有更高的可靠性;水箱分格也能够有效提高系统的可靠性;相同组件数量的条件下,串-并联系统的可靠性比并-串联系统高。该研究结果可为超高层消防供水方案比选提供一定的借鉴与参考。 In the design of the fire fighting system of super high-rise building,the different water supply methods will affect the reliability of the fire fighting system.A 230 m super high-rise complex building of commercial office in Lanzhou area is taken as the research object.By establishing a reasonable fire fighting reliability model,the reliability of the three fire fighting water supply schemes is calculated and analyzed.The influence on fire fighting reliability of high-level fire fighting water tank,water tank division setting and hybrid system is studied.The results show that:the fire fighting water supply system dominated by high pressure has higher reliability;the water tank division can also effectively improve the reliability of the system;under the condition of the same number of components,the reliability of the series-parallel system is higher than that of the parallel-series system.The research results can provide references for the comparison and selection of super high-rise fire fighting water supply schemes.
作者 高威 徐斌 李朝 GAO Wei;XU Bin;LI Zhao(College of Environmental Science and Engineering,Tongji University,Shanghai 200092,China;Tongji Architectural Design(Group)Co.,Ltd.,Shanghai 200092,China)
出处 《工程建设》 2021年第5期23-29,共7页 Engineering Construction
关键词 超高层建筑 消防系统 方案比选 可靠性模型 super high-rise building fire fighting system scheme comparison reliability model
  • 相关文献

参考文献7

二级参考文献19

共引文献45

同被引文献44

引证文献5

二级引证文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部