基于可用能和熵产分析500W/4.5K氦制冷机优化 被引量:2

Optimization of 500 W/4.5 K helium refrigerator based on exergy and entropy generation analysis
原文传递
导出
摘要 利用流程模拟软件对500 W/4.5 K氦制冷机建立静态模型,建立制冷循环的可用能效率以及系统熵产的分析公式。选取透平路分流系数、透平路中间压力、透平路进口温度和压机出口压力关键参数为研究对象,采取氦制冷机的可用能效率分析和系统熵产分析相结合的研究方法,对氦制冷流程进行优化分析。优化后的500 W/4.5 K氦制冷机的透平路分流系数为50%,透平路中间压力为4.7 bar,透平路进口温度为30 K,压机出口压力为10 bar。通过对氦制冷机的性能优化,极大提高了运行效率,减小了能耗。 A static model of 500 W/4.5 K helium refrigerator was established by process simulation software, and the exergy efficiency and entropy generation formulas were obtained. Key parameters of the turbine mass-flow ratio, turbine intermediate pressure, turbine inlet temperature and compressor outlet pressure were selected as the research objects. The available exergy efficiency and entropy generation of the helium refrigerator were adopted to optimize the helium refrigeration process. The optimized 500 W/4.5 K helium refrigerator has turbine mass-flow ratio of 50 %, turbine intermediate pressure of 4.7 bar, turbine inlet temperature of 30 K and compressor outlet pressure of 10 bar. By optimizing the performance of helium refrigerator, the operating efficiency is improved and the energy consumption is greatly reduced.
作者 张奇博 钟华勇 Zhang Qibo;Zhong Huayong(School of Mechanical Engineering,Hefei University of Technology,Hefei 230009,China;Institute of Plasma Physics,Chinese Academy of Sciences,Hefei 230031,China)
出处 《低温与超导》 CAS 北大核心 2021年第5期19-24,共6页 Cryogenics and Superconductivity
基金 安徽省自然科学基金(1908085ME163)资助。
关键词 氦制冷机 流程参数 可用能效率 熵产 优化 Helium refrigerator Process parameters Exergy efficiency Entropy generation Optimization
  • 相关文献

参考文献5

二级参考文献35

  • 1董军启,陈江平,袁庆丰,陈芝久.百叶窗翅片的传热和阻力性能试验研究[J].动力工程,2006,26(6):871-874. 被引量:11
  • 2周益民,董军启,陈江平.百叶窗翅片传热与流动的三维数值模拟[J].节能技术,2007,25(2):141-144. 被引量:12
  • 3杨世铭.传热学[M].北京:高等教育出版社,1987..
  • 4张祉佑 石秉三.低温技术原理与装置[M].北京:机械工业出版社,1987..
  • 5Tavian L. Large Cryogenic Systems at 1.8K. Proceedings of EPAC 2000, Vienna, Austria. 194 - 199.
  • 6Randal F, Barton F. Cryogenic System. England : Oxford University Press ,1985.
  • 7Adler E, Chromee B, Lohlein K, et al. Refrigeration at 1.8 K by Using a Combination of Warm Screw Compressors and Cold Two -Stage Turbo Compressors. Proceedings of ICEC17, UK, 1998, 101 - 108.
  • 8RANDALF F, BARRON. Cryogenic System[M]. England: Oxford University Press, 1985.
  • 9施锦.国产氦液化器的改造[J].低温与超导,1982(2):1-6.
  • 10Rijo Jacob Thomas, Parthasarathi Ghosh, Kanchan Chowdhury. Exergy based analysis on different expander arrangements in helium liquefiers [ J ]. International Journal of Refrigeration, 2012,354.

共引文献9

同被引文献13

引证文献2

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部