摘要 本文设计出下限为5×10^(-16)Pa·m^(3)/s的标准气体流量计,解决了超灵敏度检漏仪的量值溯源难题。采用基于固定流导法基本原理的标准气体流量计,通过激光打孔和镀膜制备的分子流导元件,成功获得下限为10^(-10)m^(3)/s的分子流导;采用电容薄膜真空计作为参考标准测量压力,将直接供气、膨胀衰减压力及标准混合气体三种方法集成在一起,为流导元件入口获得(10^(3)-10^(-6)) Pa的示漏He气分压力;采用10^(-8)m^(3)/s和10^(-10)m^(3)/s量级的两套分子流导元件,结合流导元件入口压力获得了(10^(-5)-10^(-16)) Pa·m^(3)/s的标准气体流量,设计的标准气体流量计估计合成标准不确定度为1.2%-2.8%。 The standard gas flowmeter with the lower limit of 5 × 10^(-16)Pa · m^(3)/s is designed to solve the traceability of measurement value for ultra-sensitive leak detector. The flowmeter is designed based on the constant conductance method,and the range of it is decided by the conductance of the molecular flow element and the inlet pressure of the element. The molecular flow element with the conductance of 10^(-10) m^(3)/s can be achieved by laser drilling on a platinum sheet and vacuum coating process,and the inlet partial pressure range of helium from 10^(3) to 10^(-6) Pa can be reached by combining three methods,which are the direct gas supply method,the expansion method,and the mixed gas preparation method. The standard gas flowmeter can provide gas flow with the range of( 10^(-5)-10^(-16)) Pa·m^(3)/s only using the capacitance diaphragm gauge as reference pressure standard and two molecular flow elements with the conductance of 10^(-8) m^(3)/s and 10^(-10) m^(3)/s. And the combined standard uncertainty of the flowmeter is estimated to be 1. 2% to 2. 8%.
作者 卢耀文 董云宁 杨传森 徐宇杰 闫睿 王汐月 陈俊儒 魏萌萌 郝慧萍 齐京 查良镇 LU Yaowen;DONG Yunning;YANG Chuansen;XU Yujie;YAN Rui;WANG Xiyue;CHEN Junru;WEI Mengmeng;HAO Huiping;QI Jing;CHA Liangzhen(Beijing Engineering Research Center of Vacuum Measurement and Test,Beijing 100029,China;Beijing Orient Institute of Measurement and Test,Beijing 100086,China;Tsinghua University,Beijing 100084,China)
出处 《真空科学与技术学报》 CAS CSCD 北大核心 2021年第5期422-426,共5页 Chinese Journal of Vacuum Science and Technology
关键词 超灵敏度检漏仪 固定流导法 分子流导 标准气体流量计 Ultra-sensitive leak detector Constant conductance method Molecular flow conductance Standard gas flowmeter
  • 相关文献

参考文献9

二级参考文献51

共引文献67

同被引文献42

引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部