摘要
根据多年防雷检测经历及案例,结合国家和石化行业相关规范标准,对加油机油枪过渡电阻及防静电接地电阻相关问题进行分析,阐明相关概念和术语定义及问题原因,提出预防措施、检测方法及合格判定标准。
Based on years of lightning protection detection experience and cases, combined with the relevant national and resistance of fuel dispenser nozzle, clarifies the relevant concepts, terminology definitions and the causes of problems, and puts forward preventive measures, detection methods and qualification criteria.
作者
朱紫明
张原瑞
Zhu Ziming;Zhang Yuanrui(Tongliao defense Lightning Disaster Management Center,Inner Mongolia Tongliao 028000)
出处
《内蒙古气象》
2020年第6期41-42,共2页
Meteorology Journal of Inner Mongolia
关键词
加油枪
过渡电阻
静电接地
问题分析
检测方法
Nozzle
Transition resistance
Electrostatic grounding
Problem analysis
Test method