摘要 目的探究光谱CT单能级技术联合高浓度对比剂提高冠状动脉图像质量的价值。方法40例冠状动脉疾病患者进行光谱CT检查,随机分为参照组和研究组,分别应用传统混合能级图像或高浓度对比剂获取图像。结果研究组40、50 keV各感兴趣区CT值,40、50、60、70和80 keV感兴趣区噪声,40、50、60 keV感兴趣区信噪比,40、50、60、70 keV感兴趣区对比噪声均优于参照组(P<0.05)。结论光谱CT单能级技术联合高浓度对比剂在诊断冠状动脉疾病时图像质量明显提高。 Objective To study the value of single-energy spectral CT(SESCT)with high-concentration contrast agent(HCCA)for improving the quality of coronary artery images.Methods Forty patients with coronary artery disease undergoing SESCT were randomized to control and study groups,each obtaining the images by traditional mixed energy or HCCA.Results Compared with control group,CT value of regions of interest(ROIs)at 40 and 50 keV,noise of ROIs at 40,50,60,70,and 80 keV,signal-noise ratio of ROIs at 40,50,and 60 keV,and contrast noise ratio of ROIs at 40,50,60,and 70 keV were better in study group(P<0.05).Conclusion Combined application of SESCT and HCCA can improve the image quality in the diagnosis of coronary artery disease.
作者 张继民 ZHANG Ji-min(Department of Radiology,Dongguan Hospital of Traditional Chinese Medicine,Dongguan 523320,China)
出处 《广东医科大学学报》 2021年第3期290-292,共3页 Journal of Guangdong Medical University
关键词 光谱CT单能级技术 冠状动脉疾病 对比剂 single-energy spectral CT coronary artery disease contrast agent
  • 相关文献

参考文献7

二级参考文献48

  • 1张兆琪,徐磊.同心协力,影像未来:心血管影像的发展与展望.中华放射学杂志,2013,47(1):24-26.
  • 2Dewey M,Zimmermann E,Deissenrieder F,et al.Noninvasive coronary angiography by 320-row computed tomography with lower radiation exposure and maintained diagnostic accuracy:comparison of results with cardiac catheterization in a head-tohead pilot investigation.Circulation,2009,120(10):867-875.
  • 3Leber AW,Johnson T,Becker A,et al.Diagnostic accuracy of dual-source multi-slice CT-coronary angiography in patients with an intermediate pretest likelihood for coronary artery disease.Eur Heart J,2007,28(19):2354-2360.
  • 4Fleischmann D.Use of high concentration contrast media:principles and rationale-vascular district.Eur J Radiol,2003,45(Suppl 1):S88-S93.
  • 5Cademartiri F,De Monye C,Pugliese F,et al.High iodine concentration contrast material for noninvasive multislice computed tomography coronary angiography:iopromide 370versus coronary angiography:iopromide 370 versus iomeprol400.Invest Radiol,2006,41(3):349-353.
  • 6Setty BN,Sahani DV,Ouellette-Piazzo K,et al.Comparison of enhancement,image quality,cost,and adverse reactions using 2different contrast medium concentrations for routine chest CT on16-slice MDCT.J Comput Assist Tomogr,2006,30(5):818-822.
  • 7Awai K,Inoue M,Yagyu Y,et al.Moderate versus high concentration of contrast material for aortic and hepatic enhancement and tumor to liver contrast at multidetector row CT.Radiology,2004,233(3):682-688.
  • 8Liss P,Persson PB,Hansell P,et al.Renal failure in 57 925patients undergoing coronary procedures using iso-osmolar or low-osmolar contrast media.Kidney Int,2006,70(10):1811-1817.
  • 9Seeliger E,Flemming B,Wronski T,et al.Viscosity of contrast media perturbs renal hemodynamics.J Am Soc Nephrol,2007,18(11):2912-2920.
  • 10Fei X,Du X,Yang Q,et al.64-MDCT coronary angiography:phantom study of effects of vascular attenuation on detection of coronary stenosis.Am J Roentgenol,2008,191(1):43-49.

共引文献38

同被引文献15

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部