某直升机发动机起动时频繁出现二次点火,易造成发动机涡轮间富油,导致涡轮间排气温度偏高,而且起动发电机较长时间工作于低转速的起动机状态,起动电流产生的热量无法及时散出,降低其使用寿命,甚至损坏起动发电机。针对此问题,设计了新的起动供电电路,通过降低起动供电电流,延长点火窗口期时间,有效避免了二次点火的情况,降低了起动发电机过载运行时间,提高了直升机的可靠性和维护性。
Second chance restart happens frequently on a certain helicopter engine start.This will cause over quantity of fuel in the turbine,and a higher inter turbine temperature.While the starter-generator works as a low RPM starter for a long time,the heat generated by start current cannot be dissipated in time.The heat will shorten the life of generator,even damage the generator.On this issue,design a new engine start circuit.To lengthen the ignition time,prevent second chance restart by reducing the engine start current.This could shorten the engine start time,increase the reliability and maintenance of helicopter.
作者
马静宇
关思洋
徐野夫
迟晓林
MA Jingyu;GUAN Siyang;XU Yefu;CHI Xiaolin(Harbin Hafei Aviation Industry Co.,Ltd.,Harbin 150066,China)
出处
《通信电源技术》
2021年第5期236-239,共4页
Telecom Power Technology
关键词
燃气涡轮转速
发动机电子控制单元
涡轮间排气温度
gas generator speed
engine electronic control unit
turbine outlet gas temperature