期刊文献+

二氧化氯对三种甲醛检测方法的影响研究

Influence of Chlorine Dioxide on Three Method of Measuring Formaldehyde
下载PDF
导出
摘要 主要研究二氧化氯对三种甲醛测定方法空白值的影响,结果表明:二氧化氯对AHMT法和乙酰丙酮法造成正干扰,对酚试剂法造成负干扰。二氧化氯浓度在1.0-16.0 mg/L之间,偏差为30.4%-413.0%(AHMT法),在1.0-20.0 mg/L之间,偏差为-15.0%--80.0%(酚试剂法),在0.1-3.2 mg/L之间,偏差为16.7%-233.3%(乙酰丙酮法)。对酚试剂法在0-6.0 mg/L之间的干扰程度要低于AHMT法和乙酰丙酮法;且通过实际环境空气采样,验证采样后相同含量二氧化氯溶液的偏差情况与此一致。 The influence of chlorine dioxide on three formaldehyde detection methodswas studied.The experimental results showed that chlorine dioxide caused positive interference to AHMT method and acetylacetone method,and negative interference to phenol reagent method.The concentration of chlorine dioxide was between 1.0 mg/L and 16.0 mg/L,the deviation was 30.4%to 413.0%(AHMT method),and the deviation was between 1.0 mg/L and 20.0 mg/L,and the deviation was-15.0%to-80.0%(Phenol reagent method),between 0.1 mg/L-3.2 mg/L,the deviation was 16.7%-233.3%(acetylacetone method).The interference level of the phenol reagent method between 0 mg/Land 6.0 mg/L was lower than that ofAHMT method and the acetylacetone method.And through actual ambient air sampling,it was verified that the deviation of the same content of chlorine dioxide solution after sampling was consistent with this.
作者 魏洪昭 马向东 杨玉叶 叶智坚 杨彦嘉 杨冠东 WEI Hong-zhao;MA Xiang-dong;YANG Yu-ye;YE Zhi-jian;YANG Yan-jia;YANG Guan-dong(CAS Testing Technical Services(Guangzhou)Co.,Ltd.,Guangdong Guangzhou 510650,China)
出处 《广州化工》 CAS 2021年第12期116-119,共4页 GuangZhou Chemical Industry
关键词 二氧化氯 甲醛 酚试剂 AHMT 乙酰丙酮 chlorine dioxide formaldehyde phenol reagent AHMT acetylacetone
  • 相关文献

参考文献3

二级参考文献25

  • 1岳伟,金晓滨,潘小川,丁剑.室内甲醛与成人过敏性哮喘关系的研究[J].中国公共卫生,2004,20(8):904-906. 被引量:27
  • 2华广山.二氧化氯应用于水处理消毒的探讨[J].中国市政工程,2006(5):58-59. 被引量:2
  • 3邓艳梅,杨光涛.甲醛致肥大细胞DNA损伤与诱发哮喘作用关系的初步研究[J].公共卫生与预防医学,2007,18(2):14-17. 被引量:7
  • 4乔永康,严彦,杨继文,鲁志松,杨旭.甲醛诱导获得性过敏体质致哮喘发病机理研究[J].中华微生物学和免疫学杂志,2007,27(4):298-298. 被引量:6
  • 5Hulin M, Caillaud D, Annesi-Maesano I. Indoor air pollution and childhood asthma: variations between urban and rural areas [ J ]. Indoor Air,2010,20(6) :502 -514.
  • 6Salthammer T, Mentese S, Marutzky R. Formaldehyde in the indoor environment[ J]. Chem Rev,2010,110(4) :2536 -2572.
  • 7Kim JY, Jeong MS, Park KY, et al. Aggravation of atopic dermatitis-like symptoms by consecutive low concentration of formaldehyde exposure in NC/Nga mice[J]. Exp Dermatol,2013,22(3) :219 -221.
  • 8Tang X, Bai Y, Duong A, et al. Formaldehyde in China Production, consumption, exposure levels, and health effects [ J ]. Environ Int, 2009,35(8) :1210 - 1224.
  • 9Nielsen GD, Larsen ST, Wolkoff P. Recent trend in risk assessment of formaldehyde exposures from indoor air[J]. Arch Toxicol,2013,87 (1) :73 -98.
  • 10World Health Organization. Concise international chemical assessment document 40 : formaldehyde [ R ]. Geneva: World Health Organization, 2002.

共引文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部