期刊文献+

Accuracy Assessment of a Novel Radiographic Method to Evaluate Guided Bone Regeneration Outcomes Using a 3D-Printed Model 被引量:1

原文传递
导出
摘要 The aim of this study was to evaluate the accuracy and reproducibility of a morphological contour interpolation(MCI)based segmentation method for the volumetric measurement of bone grafts around implants.Three 3D-printed models(one with a cylinder and two with a geometrically-complex form)were fabricated to simulate implant placement with a simultaneous guided bone regeneration(GBR)procedure.All models were scanned using a cone beam computed tomography(CBCT)instrument with the same parameters.The true volumes of the bone grafts in the models were assessed using computer-aided calculation(controls).For the test measurements,both manual and MCI-based methods were used.A comparison between the measured and true volumes was performed to evaluate the accuracy.The coefficients of variation of repeated measurements were calculated to evaluate the reproducibility.In addition,the execution time was recorded and a comparison between the two methods was performed.The high accuracy of the MCI-based method was found with differences between the measured value and actual volume,which never exceeded 7.3%.Excellent reproducibility was shown,with coefficients of variation never exceeding 1.1%.A shorter execution time was observed for the MCI-based method than for the manual method.Within the confines of this study,the MCI-based method may be suitable for volumetric measurements of grafted bone around implants.
作者 SHI Jumngyu LI Yuan ZHANG Xiao ZHANG Xiaomeng LAI Hongchang 史俊宇;李元;张枭;张晓梦;赖红昌(Department of Implant Dentistry,Shanghai Ninth People’s Hospital,Shanghai Jiao Tong University School of Medicine,Shanghai,200011,China;College of Stomatology,Shanghai Jiao Tong University,Shanghai,200011,China;National Center for Stomatology,National Clinical Research Center for Oral Diseases,Shanghai,200011,China;Shanghai Key Laboratory of Stomatology,Shanghai,200011,China)
出处 《Journal of Shanghai Jiaotong university(Science)》 EI 2021年第3期284-289,共6页 上海交通大学学报(英文版)
基金 the Project of Science and Technology Commission of Shanghai Municipality(No.19411950100) the Multicenter Clinical Research Program of Shanghai Jiao Tong University School of Medicine(No.DLY201822) the Fundamental Research Program Funding of Ninth People’s Hospital affiliated to Shanghai Jiao Tong University School of Medicine(No.JYZZ102)。
  • 相关文献

参考文献1

二级参考文献27

  • 1Scarfe WC, Farman AG, Sukovic P. Clinical applications of cone-beam computed tomography in dental practice. J Can Dent Assoc 2006;72:75-80.
  • 2Dawood A, Patel S, Brown J. Cone beam CT in dental practice. Br Dent J 2009;207:23-8.
  • 3Watanabe H, Honda E, Tetsumura A, Kurabayashi T. A comparative study for spatial resolution and subjective image characteristics of a multi-slice CT and a cone-beam CT for dental use. Eur J Radiol 2009;77:397-402.
  • 4Bartling SH, Majdani O, Gupta R, Rodt T, Dullin C, Fitzgerald PF, et al. Large scan field, high spatial resolution flat-panel detector based volumetric CT of the whole human skull base and for maxillofacial imaging. Dentomaxillofac Radiol 2007;36:317-27.
  • 5Scarfe WC, Farman AG, Levin MD, Gane D. Essentials of maxillofacial cone beam computed tomography. Alpha Omegan 2010; 103:62-7.
  • 6Scarfe WC, Farman AG. What is cone-beam CT and how does it work? Dent Clin North Am 2008;52:707-30.
  • 7Li W, Chen F, Zhang F, Ding W, Ye Q, Shi J, et al. Volumetric measurement of root resorption following molar mini-screw implant intrusion using cone beam computed tomography. PLoS One 2013;8:e60962.
  • 8Lee R J, Weissheimer A, Pham J, Go L, de Menezes LM, Redmond WR, et al. Three-dimensional monitoring of root movement during orthodontic treatment. Am J Orthod Dentofaeial Orthop 2015;147:132-42.
  • 9Kobayashi K, Shimoda S, Nakagawa Y, Yamamoto A. Accuracy in measurements of distance using limited cone-beam computerized tomography, lnt J Oral Maxillofac Implants 2004;19:228-30.
  • 10Han G, Huang S, Von den Hoff JW, Zeng X, Kuijpers-Jagtman AM. Root resorption after orthodontic intrusion and extrusion: An intraindividual study. Angle Orthod 2005;75:912-8.

共引文献6

同被引文献18

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部