期刊文献+

高频红外碳硫分析仪测定磷矿石中碳的含量

Determination of Carbon Content in Phosphate Rock by High Frequency Infrared Analyzer
下载PDF
导出
摘要 本试验使用HCS-KR200高频红外碳硫分析仪测定磷矿石中碳含量。称取于105℃烘干样品0.0400g,加入0.2000g三氧化钼,混匀,加入0.5g纯铁助熔剂,1.5g钨粒助熔剂,到高频红外碳硫分析仪上测定。此方法操作步骤简单,精确度较高、检测数据比较稳定。方法精度0.0010%~100%。符合磷矿石中碳分析质量要求。 The content of carbon in phosphate rock was determined by HCS-KR200 high frequency infrared carbon sulfur analyzer.The samples were dried at 105℃with 0.0400G,mixed with 0.2000G Molybdenum trioxide,mixed with 0.5g pure iron flux and 1.5g tungsten flux.The method has the advantages of simple operation flow,high accuracy and stable detection result.The precision of the method is 0.0010%~100%.It can meet the quality requirement of carbon analysis in phosphate rock.
作者 张瑶 ZHANG Yao(Yunnan General Office of China Building Materials Industry Geological Prospecting Center,Kunming 650106,China)
出处 《价值工程》 2021年第14期248-249,共2页 Value Engineering
关键词 高频红外碳硫分析仪 磷矿石 碳含量 high frequency infrared carbon sulfur analyzer phosphate ore carbon content